ABSTRACT
In December 2020, WHO presented the first international standard (WHO IS) for anti-SARS-CoV-2 immunoglobulin. This standard is intended to serve as a reference reagent against which serological tests can be calibrated, thus creating better comparability of results between different tests, laboratories, etc. Here, we have examined three different commercial ELISA kits for the quantification of SARS-CoV-2 IgG antibodies, namely the Anti-SARS-CoV-2 QuantiVac ELISA (IgG) (Euroimmun, Lübeck, Germany), the SERION ELISA agile (Institut Virion Serion, Würzburg, Germany), and the COVID-19 quantitative IgG ELISA (DeMediTec Diagnostics, Kiel, Germany). According to the manufacturers, all are calibrated against the WHO IS and can provide results in either international units (IU) (DeMediTec) or arbitrary antibody units (BAU) per milliliter (Euroimmun, Virion Serion), which are numerically identical, according to the WHO. A total of 50 serum samples from vaccinated individuals were tested side by side and according to the manufacturer's instructions. We compared the test results of all three assays with each other to assess comparability and with a quantitative in-house virus neutralization test (micro-NT). In summary, our data are consistent with other studies published on this topic that tested similar assays from different manufacturers. Overall, the agreement between quantitative ELISAs is variable and cannot be used interchangeably despite calibration against a standard. Therefore, interpretation of results must still be individualized and tailored to each case. More importantly, our results highlight that quantitative ELISAs in their current form cannot replace neutralization tests.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: SARS-CoV-2 / COVID-19 Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article