Measuring Foot Abduction Brace Wear Time Using a Single 3-Axis Accelerometer.
Griffiths, Benjamin; Silver, Natan; Granat, Malcolm H; Lebel, Ehud.
Afiliação
  • Griffiths B; School of Health and Society, University of Salford, Salford M5 4WT, UK.
  • Silver N; Shaare Zedek Medical Center, Jerusalem 9103102, Israel.
  • Granat MH; School of Health and Society, University of Salford, Salford M5 4WT, UK.
  • Lebel E; Shaare Zedek Medical Center, Jerusalem 9103102, Israel.
Sensors (Basel) ; 22(7)2022 Mar 22.
Article em En | MEDLINE | ID: mdl-35408046
ABSTRACT
The recommended treatment for idiopathic congenital clubfoot deformity involves a series of weekly castings, surgery, and a period of bracing using a foot abduction brace (FAB). Depending on the age of the child, the orthotic should be worn for periods that reduce in duration as the child develops. Compliance is vital to achieve optimal functional outcomes and reduce the likelihood of reoccurrence, deformity, or the need for future surgery. However, compliance is typically monitored by self-reporting, which is time-consuming to implement and lacks accuracy. This study presents a novel method for objectively monitoring FAB wear using a single 3-axis accelerometer. Eleven families mounted an accelerometer on their infant's FAB for up to seven days. Parents were also given a physical diary that was used to record the daily application and removal of the orthotic in line with their treatment. Both methods produced very similar measurements of wear that visually aligned with the movement measured by the accelerometer. Bland Altman plots showed a -0.55-h bias in the diary measurements and the limits of agreement ranging from -2.96 h to 1.96 h. Furthermore, the Cohens Kappa coefficient for the entire dataset was 0.88, showing a very high level of agreement. The method provides an advantage over existing objective monitoring solutions as it can be easily applied to existing FABs, preventing the need for bespoke monitoring devices. The novel method can facilitate increased research into FAB compliance and help enable FAB monitoring in clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pé Torto Equinovaro / Órtoses do Pé Limite: Child / Humans / Infant Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pé Torto Equinovaro / Órtoses do Pé Limite: Child / Humans / Infant Idioma: En Ano de publicação: 2022 Tipo de documento: Article