Your browser doesn't support javascript.
loading
Hounsfield unit measurement method and related factors that most appropriately reflect bone mineral density on cervical spine computed tomography.
Han, Kyungmin; You, Soon Tae; Lee, Ho Jin; Kim, Il Sup; Hong, Jae Taek; Sung, Jae Hoon.
Afiliação
  • Han K; Department of Neurosurgery, College of Medicine, St. Vincent Hospital, The Catholic University of Korea, 93-6 Ji-Dong, Paldal-gu, Suwon, 442-723, Korea.
  • You ST; Department of Neurosurgery, College of Medicine, St. Vincent Hospital, The Catholic University of Korea, 93-6 Ji-Dong, Paldal-gu, Suwon, 442-723, Korea.
  • Lee HJ; Department of Neurosurgery, College of Medicine, St. Vincent Hospital, The Catholic University of Korea, 93-6 Ji-Dong, Paldal-gu, Suwon, 442-723, Korea. rhother@hanmail.net.
  • Kim IS; Department of Neurosurgery, College of Medicine, St. Vincent Hospital, The Catholic University of Korea, 93-6 Ji-Dong, Paldal-gu, Suwon, 442-723, Korea.
  • Hong JT; Department of Neurosurgery, College of Medicine, Eunpyeong St. Mary's Hospital, The Catholic University of Korea, Seoul, Korea.
  • Sung JH; Department of Neurosurgery, College of Medicine, St. Vincent Hospital, The Catholic University of Korea, 93-6 Ji-Dong, Paldal-gu, Suwon, 442-723, Korea.
Skeletal Radiol ; 51(10): 1987-1993, 2022 Oct.
Article em En | MEDLINE | ID: mdl-35419706
ABSTRACT

OBJECTIVE:

Our study's purpose was to determine the most reliable Hounsfield unit (HU) measurement method to reflect bone mineral density (BMD) on cervical spine computed tomography (CT) and to identify any factors that influence these results. MATERIALS AND

METHODS:

We retrospectively analyzed 439 consecutive patients with mild head and neck injuries. Mean HU values of the C2-C7 vertebra were determined on each sagittal, coronal, and axial CT image. Correlation patterns were analyzed between the HU value and corresponding dual-energy X-ray absorptiometry (DXA) in the lumbar vertebra (T-score) and femoral neck (T-score). A sub-group analysis was performed according to patient age, sex, and degree of spinal degeneration.

RESULTS:

The correlation coefficients for HU and DXA ranged from 0.52 to 0.65 in all cervical segments. A simple linear regression analysis revealed the following formula T-score = 0.01 × (HU) - 4.55. The mean HU values for osteopenia and osteoporosis were 284.0 ± 63.3 and 231.5 ± 52.8, respectively. The ROC curve indicated that the HU method has a sensitivity of 89.2% and specificity of 88.7% to diagnose osteoporosis. The HU measurement showed a high correlation value (range r = 0.64-0.70) with spine DXA score regardless of the degree of degeneration or patient age or sex.

CONCLUSION:

HU values using the upper two cervical vertebrae (C2 and C3) reflected a more reliable BMD level than other segments. Additionally, the HU of cervical CT provided reliable information regardless of measurement plane, age or sex, and degree of degeneration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoporose / Densidade Óssea Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoporose / Densidade Óssea Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article