Your browser doesn't support javascript.
loading
Comparative Analysis of Preoperative High Frequency Color Doppler Ultrasound versus MR Lymphangiography versus ICG Lymphography of Lymphatic Vessels in Lymphovenous Anastomosis.
Kim, Hyung Bae; Jung, Sung Soo; Cho, Min-Jeong; Peirera, Nicolas; Pak, Changsik John; Suh, Peter Hyun Suk; Lee, Sang Hoon; Hong, Joon Pio.
Afiliação
  • Kim HB; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Jung SS; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Cho MJ; Department of Plastic and Reconstructive Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio.
  • Peirera N; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Pak CJ; Department of Plastic Surgery and Burns, Hospital del Trabajador, Santiago, Chile.
  • Suh PHS; Department of Plastic Surgery, Clínica Las Condes, Santiago, Chile.
  • Lee SH; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Hong JP; Department of Plastic and Reconstructive Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
J Reconstr Microsurg ; 39(2): 92-101, 2023 Feb.
Article em En | MEDLINE | ID: mdl-35426085
ABSTRACT

BACKGROUND:

Despite the extensive use of various imaging modalities, there is limited literature on comparing the reliability between indocyanine green (ICG) lymphography, MR Lymphangiogram (MRL), and high frequency color Doppler ultrasound (HFCDU) to identify lymphatic vessels.

METHOD:

In this study of 124 patients, the correlation between preoperative image findings to the actual lymphatic vessel leading to lymphovenous anastomosis (LVA) was evaluated. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and simple detection were calculated. Subgroup analysis was also performed according to the severity of lymphedema.

RESULTS:

Total of 328 LVAs were performed. The HFCDU overall had significantly higher sensitivity for identifying lymphatic vessels (99%) over MRL (83.5%) and ICG lymphography (82.3%)(p < 0.0001). Both ICG lymphography and HFCDU had 100% specificity and PPV. The NPV was 3.6%, 6.5% and 57.1% respectively for MRL, ICG lymphography, and HFCDU. All modalities showed high sensitivity for early stage 2 lymphedema while HFCDU showed a significantly higher sensitivity for late stage 2 (MRL79.7%, ICG83.1%, HFCDU97%) and stage 3 (MRL79.7%, ICG79.7%, HFCDU100%) over the other two modalities (p < 0.0001).

CONCLUSION:

This study demonstrated while all three modalities are able to provide good information, the sensitivity may alter as the severity of lymphedema progresses. The HFCDU will provide the best detection for lymphatic vessels throughout all stages of lymphedema. However, as each modality provides different and unique information, combining and evaluating the data according to the stage of lymphedema will be able to maximize the chance for a successful surgical outcome.