Your browser doesn't support javascript.
loading
Development of a liquid chromatography mass spectrometry method for the determination of vitamin K1, menaquinone-4, menaquinone-7 and vitamin K1-2,3 epoxide in serum of individuals without vitamin K supplements.
Meinitzer, Andreas; Enko, Dietmar; Zelzer, Sieglinde; Prüller, Florian; Alonso, Nerea; Fritz-Petrin, Eva; Herrmann, Markus.
Afiliação
  • Meinitzer A; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Graz, Austria.
  • Enko D; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Graz, Austria.
  • Zelzer S; Institute of Clinical Chemistry and Laboratory Medicine, General Hospital Hochsteiermark, Leoben, Austria.
  • Prüller F; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Graz, Austria.
  • Alonso N; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Graz, Austria.
  • Fritz-Petrin E; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Graz, Austria.
  • Herrmann M; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, Graz, Austria.
Clin Chem Lab Med ; 60(7): 1011-1019, 2022 06 27.
Article em En | MEDLINE | ID: mdl-35427444
OBJECTIVES: Vitamin K and metabolites have a beneficial role in blood coagulation, bone metabolism and growth. However, the determination of vitamin K concentrations in the blood in patients consuming a diet with naturally occurring vitamin K is currently challenging. We aim to develop a cost-effective and rapid method to measure vitamin K metabolites with potential application for clinics and research. METHODS: We developed a simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for the determination of vitamin K1, menaquinone-4 (MK-4), menaquinone-7 (MK-7) and vitamin K1-2,3 epoxide in human serum and validated the method in a study cohort of 162 patients tested for carbohydrate malabsorption and in 20 patients with oral phenprocoumon intake. RESULTS: The overall precision (CVs) ranged between 4.8 and 17.7% in the specified working range (0.06-9.0 nmol/L for all analytes except for MK-7 with 0.04-6.16 nmol/L). In the malabsorption cohort samples, measured values were obtained for all different vitamin K metabolites except for vitamin K1-2,3 epoxide. This metabolite could be detected only in patients with phenprocoumon intake. The good performance of the method is especially achieved by the interaction of three factors: the use of lipase in the sample preparation, the use of an atypical fluorinated reversed phase column, and a logarithmic methanol gradient. CONCLUSIONS: The described method is able to determine the concentration of four vitamin K metabolites in a time-efficient, simple and cost-effective manner. It can be suitable for both routine clinics and research.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina K 1 / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitamina K 1 / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article