Is breast ultrasound a good alternative to magnetic resonance imaging for evaluating implant integrity?
Secco, G M; Gutierrez, P A; Secco, V L; Chico, M J; Secco, R A; Pesce, K A.
Afiliação
  • Secco GM; Servicio de Diagnóstico por Imágenes, Hospital Italiano de Buenos Aires, Ciudad Autónoma de Buenos Aires, Argentina. Electronic address: giannina.secco@hospitalitaliano.org.ar.
  • Gutierrez PA; Servicio de Diagnóstico por Imágenes, Hospital Italiano de Buenos Aires, Ciudad Autónoma de Buenos Aires, Argentina.
  • Secco VL; Sección Diagnóstico e Intervencionismo Mamario, Servicio de Diagnóstico por Imágenes, Hospital Italiano de Buenos Aires, Ciudad Autónoma de Buenos Aires, Argentina.
  • Chico MJ; Sección Diagnóstico e Intervencionismo Mamario, Servicio de Diagnóstico por Imágenes, Hospital Italiano de Buenos Aires, Ciudad Autónoma de Buenos Aires, Argentina.
  • Secco RA; Sección Diagnóstico e Intervencionismo Mamario, Servicio de Diagnóstico por Imágenes, Hospital Italiano de Buenos Aires, Ciudad Autónoma de Buenos Aires, Argentina.
  • Pesce KA; Sección Diagnóstico e Intervencionismo Mamario, Servicio de Diagnóstico por Imágenes, Hospital Italiano de Buenos Aires, Ciudad Autónoma de Buenos Aires, Argentina.
Radiologia (Engl Ed) ; 64 Suppl 1: 20-27, 2022 Mar.
Article em En | MEDLINE | ID: mdl-35428463
ABSTRACT

OBJECTIVE:

To compare the diagnostic performance of breast ultrasound and breast magnetic resonance imaging and to correlate the findings on the two techniques that are suggestive of implant rupture. MATERIAL AND

METHODS:

We reviewed the images and reports of breast ultrasound and magnetic resonance imaging studies done in our diagnostic and interventional breast imaging unit to evaluate breast implants in 205 patients between January 2015 and December 2017.

RESULTS:

Ultrasound findings were compatible with implant rupture in 87 (42.4%) patients intracapsular rupture in 44 (21.5%) and intracapsular and extracapsular rupture in 43 (21.0%). Ultrasound yielded 85.2% sensitivity, 89.7% specificity, 86.2% positive predictive value, and 89.0% negative predictive value. Magnetic resonance imaging findings were compatible with implant rupture in 88 (42.9%) patients intracapsular rupture in 50 (24.4%) and intracapsular and extracapsular rupture in 38 (18.5%). The correlation between positive findings for the location of the rupture on the two imaging techniques was excellent (0.77; p < 0.0001).

CONCLUSION:

We found high concordance between the two techniques for the detection of intracapsular and extracapsular implant rupture. These results consolidate the use of ultrasound as the first-line imaging technique to evaluate implant integrity in our population; magnetic resonance imaging can be reserved for cases in which the ultrasound diagnosis of implant integrity is uncertain.