Effect of repeated millings on the surface integrity of diamond burs and roughness of different CAD/CAM materials.
Ceylan, Gülsüm; Emir, Faruk; Dogdu, Canan; Demirel, Münir; Özcan, Mutlu.
Afiliação
  • Ceylan G; Department of Prosthodontics, School of Dentistry, Istanbul Medipol University, Istanbul, Turkey. gulsumcyln@gmail.com.
  • Emir F; Department of Prosthodontics, Gülhane Faculty of Dentistry, Health Sciences University, Ankara, Turkey.
  • Dogdu C; Department of Prosthodontics, School of Dentistry, Istanbul Medipol University, Istanbul, Turkey.
  • Demirel M; Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey.
  • Özcan M; Division of Dental Biomaterials, Center for Dental Medicine, Clinic Reconstructive Dentistry, University of Zürich, Zurich, Switzerland.
Clin Oral Investig ; 26(8): 5325-5337, 2022 Aug.
Article em En | MEDLINE | ID: mdl-35449245
ABSTRACT

OBJECTIVES:

This study evaluated the surface integrity of two types of diamond burs and their effect on the roughness of different CAD/CAM materials. MATERIALS AND

METHODS:

CAD/CAM materials, Vita Mark II (VM), IPS e.max CAD (EM), Celtra Duo (CD), G-Ceram (GC), and Lava Ultimate (LU) blocks were milled with CEREC MCXL. Five pairs of pointed cylinder burs (CB) and step burs (SB) were used repeatedly. The wear rate of burs was analyzed before and after milling with a scanning electron microscope (SEM) and weighing the burs. The milling time of the blocks at different milling stages was recorded from 2 (M2) to 8 times (M8) of use. The surface roughness (Ra) of blocks was measured with a profilometer. Data from the differences in surface roughness were analyzed using univariate analyses of variance and Kruskal-Wallis tests (alpha = 0.05).

RESULTS:

For M2, the highest roughness (2.12 ± 0.1 µm) was observed with the VM block. EM blocks presented the highest roughness values (1.82 ± 0.3 µm, 1.85 ± 0.1 µm, and 1.86 ± 0.04 µm) at M4, M6, and M8, respectively. While the highest Ra values were observed for VM (2.12 to 1.43 µm), LU provided the lowest mean Ra (1.62 to 1.33 µm) among the tested materials. After the repeated use of burs up to 8 times, the surface roughness of all the tested materials decreased. Milling of LU resulted in chip deposits on the CB surface in SEM images. The duration of cutting was higher for CD and EM materials than those of other materials, but the milling duration for VM, GC, and LU blocks was similar. SB burs exhibited more wear than CB after repeated milling.

CONCLUSIONS:

A repeated number of millings more than 4 times decreased the surface integrity of the milling burs, increased the surface roughness of CAD/CAM blocks except for LU, and increased the milling duration. Increased material hardness was more detrimental on bur surface integrity. CLINICAL RELEVANCE During milling CAD/CAM blocks, clinicians should note that the surface integrity of milling burs decreases after 4 times of use as a function of material hardness where step burs wear quicker than pointed cylinder burs.