Your browser doesn't support javascript.
loading
Intra-rater reliability and feasibility of the HexCom advanced disease complexity assessment model.
Busquet-Duran, Xavier; Esteban-Perez, Manel; Manresa-Domínguez, Josep Maria; Moreno, Susana Martin; Leston-Lado, Lola; Torán-Monserrat, Pere.
Afiliação
  • Busquet-Duran X; Home Care Program, Granollers Support Team (PADES), Vallès Oriental Primary Health Care Services, Catalan Institute of Health, Granollers, Barcelona, Spain; Sant Miquel Primary Care Center (CAP), Carrer de Francesc Macià i Llussà, 154, 08401 Granollers, Barcelona, Catalonia, Spain; Multidisciplinary
  • Esteban-Perez M; Home Care Program, Reus Support Team (PADES), Sant Joan de Reus University Hospital, Avinguda del Doctor Josep Laporte, 2, 43204 Reus, Tarragona, Spain.
  • Manresa-Domínguez JM; Multidisciplinary Research Group on Health and Society (GREMSAS), (2017 SGR 917), 08007 Barcelona, Spain; Metropolitan Nord Unit of Research Support, Jordi Gol University Institute of Research in Primary Care (IDIAP), Mataró, Barcelona, Gran Via de les Corts Catalanes, 587, 08007 àtic, Catalonia, Sp
  • Moreno SM; Home Care Program, Granollers Support Team (PADES), Vallès Oriental Primary Health Care Services, Catalan Institute of Health, Granollers, Barcelona, Spain; Sant Miquel Primary Care Center (CAP), Carrer de Francesc Macià i Llussà, 154, 08401 Granollers, Barcelona, Catalonia, Spain.
  • Leston-Lado L; Home Care Program, Granollers Support Team (PADES), Vallès Oriental Primary Health Care Services, Catalan Institute of Health, Granollers, Barcelona, Spain; Sant Miquel Primary Care Center (CAP), Carrer de Francesc Macià i Llussà, 154, 08401 Granollers, Barcelona, Catalonia, Spain.
  • Torán-Monserrat P; Multidisciplinary Research Group on Health and Society (GREMSAS), (2017 SGR 917), 08007 Barcelona, Spain; Metropolitan Nord Unit of Research Support, Jordi Gol University Institute of Research in Primary Care (IDIAP), Mataró, Barcelona, Gran Via de les Corts Catalanes, 587, 08007 àtic, Catalonia, Sp
Aten Primaria ; 54(6): 102343, 2022 06.
Article em En | MEDLINE | ID: mdl-35550948
ABSTRACT

AIM:

To study the intra-rater reliability and feasibility of the HexCom complexity assessment model by analyzing internal consistency, intra-rater reliability and response time.

DESIGN:

Test-retest study with a selection of 11 clinical situations that cover the full scope of situations assessed by the HexCom model and which are responded to individually. LOCATION Home care, primary care, hospital and sociosanitary care. Two specialized palliative home care teams (PADES).

PARTICIPANTS:

A total of 20 professionals comprising 10 experts in palliative home care (PADES) and 10 professionals from general palliative care (primary care, hospital and sociosanitary care). These professionals came from the fields of family medicine (5), internal medicine (2), geriatrics (2), nursing (9), psychology (1) and social work (1). MAIN MEASUREMENTS Cronbach's alpha, weighted kappa, response time.

RESULTS:

Cronbach's alpha of 0.91 for HexCom-Red and 0.87 for HexCom-Clin. Intra-rater reliability ranging from good to very good for HexCom-Red (kappa 0.78-1) and from moderate to very good for HexCom-Clin (kappa 0.58-0.91). Average response time of 057 for HexCom-Red and 380min for HexComClin.

CONCLUSIONS:

HexCom-Red and HexCom-Clin are reliable tools and feasible for use by all professionals involved in both general and specialized palliative care at different levels.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cuidados Paliativos / Serviços de Assistência Domiciliar Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cuidados Paliativos / Serviços de Assistência Domiciliar Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article