Your browser doesn't support javascript.
loading
A Simple, Robust, and Convenient HPLC Assay for Urinary Lactulose and Mannitol in the Dual Sugar Absorption Test.
Sequeira, Ivana R; Kruger, Marlena C; Hurst, Roger D; Lentle, Roger G.
Afiliação
  • Sequeira IR; Human Nutrition Unit, School of Biological Sciences, University of Auckland, Auckland 1024, New Zealand.
  • Kruger MC; School of Health Sciences, College of Health, Massey University, Palmerston North 4472, New Zealand.
  • Hurst RD; Food Innovation Portfolio, The New Zealand Institute for Plant & Food Research Ltd., Palmerston North 4474, New Zealand.
  • Lentle RG; School of Health Sciences, College of Health, Massey University, Palmerston North 4472, New Zealand.
Molecules ; 27(9)2022 Apr 21.
Article em En | MEDLINE | ID: mdl-35566024
ABSTRACT

BACKGROUND:

Heterogeneous laborious analytical methodologies for the determination of urinary lactulose and mannitol limit their utility in intestinal permeability testing.

METHODS:

We developed an assay using a Shimadzu HPLC system, an Aminex HPX87C column, and refractive index detection. The test was calibrated using a series of dilutions from standard stock solutions of lactulose and mannitol 'spiked' into urine samples. The utility to quantify urinary excretion during the dual sugar absorption test over 6 h was also determined.

RESULTS:

Lactulose and mannitol were eluted isocratically at 5.7 and 10.1 min, respectively, with water as a mobile phase at a flow rate of 0.3 mL min-1, 858 psi, 60 °C. The calibration curves for both sugars were linear up to 500 µg mL-1 with a limit of detection in standard solutions at 4 µg mL-1 and in 'spiked' urine samples at 15 µg mL-1. The intra-assay and inter-assay CVs were between 2.0-5.1% and 2.0-5.1% for lactulose and 2.5-4.4% and 2.8-3.9% for mannitol. The urinary profiles of the 6 h absorption of lactulose and mannitol showed similar peak-retention times to standard solutions and were well-resolved at 5.9 and 10.4 min, respectively.

CONCLUSIONS:

The assay was easy to automate, using commonly available equipment and convenient requiring no prior laborious sample derivatization. The simplicity, reproducibility, and robustness of this assay facilitates its use in routine clinical settings for the quantification of intestinal permeability.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lactulose / Manitol Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Lactulose / Manitol Idioma: En Ano de publicação: 2022 Tipo de documento: Article