Your browser doesn't support javascript.
loading
Cardiac Segmentation Method Based on Domain Knowledge.
Wang, Yingni; Chen, Wenbin; Tang, Tianhong; Xie, Wenquan; Jiang, Yong; Zhang, Huabin; Zhou, Xiaobo; Yuan, Kehong.
Afiliação
  • Wang Y; Graduate School at Shenzhen, Tsinghua University, Shenzhen, China.
  • Chen W; Department of Echocardiography, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, China.
  • Tang T; Department of Echocardiography, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, China.
  • Xie W; Graduate School at Shenzhen, Tsinghua University, Shenzhen, China.
  • Jiang Y; Department of Echocardiography, Fuwai Hospital Chinese Academy of Medical Sciences, Shenzhen, China.
  • Zhang H; Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, China.
  • Zhou X; School of Biomedical Informatics, University of Texas Health Sciences Center at Houston, Houston, TX, USA.
  • Yuan K; Graduate School at Shenzhen, Tsinghua University, Shenzhen, China.
Ultrason Imaging ; 44(2-3): 105-117, 2022 05.
Article em En | MEDLINE | ID: mdl-35574925
ABSTRACT
Echocardiography plays an important role in the clinical diagnosis of cardiovascular diseases. Cardiac function assessment by echocardiography is a crucial process in daily cardiology. However, cardiac segmentation in echocardiography is a challenging task due to shadows and speckle noise. The traditional manual segmentation method is a time-consuming process and limited by inter-observer variability. In this paper, we present a fast and accurate echocardiographic automatic segmentation framework based on Convolutional neural networks (CNN). We propose FAUet, a segmentation method serially integrated U-Net with coordinate attention mechanism and domain feature loss from VGG19 pre-trained on the ImageNet dataset. The coordinate attention mechanism can capture long-range dependencies along one spatial direction and meanwhile preserve precise positional information along the other spatial direction. And the domain feature loss is more concerned with the topology of cardiac structures by exploiting their higher-level features. In this research, we use a two-dimensional echocardiogram (2DE) of 88 patients from two devices, Philips Epiq 7C and Mindray Resona 7T, to segment the left ventricle (LV), interventricular septal (IVS), and posterior left ventricular wall (PLVW). We also draw the gradient weighted class activation mapping (Grad-CAM) to improve the interpretability of the segmentation results. Compared with the traditional U-Net, the proposed segmentation method shows better performance. The mean Dice Score Coefficient (Dice) of LV, IVS, and PLVW of FAUet can achieve 0.932, 0.848, and 0.868, and the average Dice of the three objects can achieve 0.883. Statistical analysis showed that there is no significant difference between the segmentation results of the two devices. The proposed method can realize fast and accurate segmentation of 2DE with a low time cost. Combining coordinate attention module and feature loss with the original U-Net framework can significantly increase the performance of the algorithm.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Cinética por Ressonância Magnética / Coração Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imagem Cinética por Ressonância Magnética / Coração Tipo de estudo: Guideline / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article