Using Intra-Operative Laryngeal Ultrasonography as a Real-Time Tool in Assessing Vocal Cord Function During Radiofrequency Ablation of the Thyroid Gland.
Fung, Matrix Man Him; Lang, Brian Hung Hin.
Afiliação
  • Fung MMH; Division of Endocrine Surgery, Department of Surgery, the University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR, China.
  • Lang BHH; Division of Endocrine Surgery, Department of Surgery, the University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR, China. blang@hku.hk.
World J Surg ; 46(9): 2206-2211, 2022 09.
Article em En | MEDLINE | ID: mdl-35595868
ABSTRACT

BACKGROUND:

Inadvertent injury of the recurrent laryngeal nerve can occur during radiofrequency ablation (RFA) of thyroid nodules. Methods to avoid permanent injury have not been described. Laryngeal ultrasonography (LUSG) can assess the function of vocal cords (VCs) in real time. The present study aimed to evaluate the feasibility and accuracy of LUSG in assessing real-time VC function during RFA of benign thyroid nodules.

METHODS:

Consecutive patients undergoing RFA for benign thyroid nodules under local anesthesia were included. Spontaneous VC movements were checked with intra-operative LUSG (iLUSG) following each transverse ablation plane. In case of reduced VC movement, the ablation was stopped immediately. Post-ablation VC function was rechecked by LUSG on day-0 and flexible laryngoscopy (FL) on day-7. A concordance with day-0 LUSG or day-7 FL was a "true positive" or "true negative" depending on the presence or absence of VC palsy (VCP). Accuracy was calculated as the sum of all true positives and negatives divided by total nerves-at-risk.

RESULTS:

Of 65 eligible patients, 56 (86.2%) were females. Twelve (18.5%) patients had bilateral lobe RFA, while 53 (81.5%) had unilateral RFA. The total number of nerves-at-risk was 77. Three unilateral VCPs (3.9%) were initially detected on iLUSG and confirmed by day-0 LUSG. All recovered fully within one week. The overall accuracy of iLUSG was 100%.

CONCLUSION:

iLUSG is a highly accurate method that permits real-time feedback on the function of the VCs during RFA procedure. Real-time detection of VCP may prevent permanent injury. Methodological routine use of iLUSG is recommended during thyroid RFA.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nódulo da Glândula Tireoide / Ablação por Cateter / Ablação por Radiofrequência Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nódulo da Glândula Tireoide / Ablação por Cateter / Ablação por Radiofrequência Tipo de estudo: Diagnostic_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article