Usefulness of Temporary Pacing in Patients With New Left Bundle Branch Block During Transcatheter Aortic Valve Implantation.
Chezar-Azerrad, Chava; Brar, Vijaywant; Nawaz, Amna; Forrestal, Brian J; Yerasi, Charan; Case, Brian C; Medranda, Giorgio A; Musallam, Anees; Ben-Dor, Itsik; Wermers, Jason P; O'Donoghue, Susan; Satler, Lowell F; Rogers, Toby; Waksman, Ron.
Afiliação
  • Chezar-Azerrad C; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Brar V; Section of Electrophysiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Nawaz A; Georgetown University School of Medicine, Washington, District of Columbia.
  • Forrestal BJ; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Yerasi C; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Case BC; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Medranda GA; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Musallam A; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Ben-Dor I; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Wermers JP; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • O'Donoghue S; Section of Electrophysiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Satler LF; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia.
  • Rogers T; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia; Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland.
  • Waksman R; Section of Interventional Cardiology, MedStar Washington Hospital Center, Washington, District of Columbia. Electronic address: Ron.Waksman@medstar.net.
Am J Cardiol ; 176: 105-111, 2022 08 01.
Article em En | MEDLINE | ID: mdl-35641348
ABSTRACT
New-onset left bundle branch block (NLBBB) is the most common complication after transcatheter aortic valve implantation (TAVI). Expert consensus recommends temporary transvenous pacemaker (TTVP) support for 24 hours in these patients. To date, no study has examined TTVP use during the index hospitalization in detail. Therefore, we aimed to assess TTVP use in patients with TAVI who developed NLBBB. In this prospective observational study, we performed a detailed analysis of 24-hour telemetry in patients who developed NLBBB during TAVI. Baseline characteristics and procedural and postprocedural data were recorded. The primary outcome was pacing by the TTVP. We evaluated inappropriate TTVP use, electrophysiology study findings, permanent pacemaker (PPM) implantation, and NLBBB resolution. A total of 83 patients (74.4 ± 8.7 years, 41% female) developed NLBBB during TAVI. During index hospitalization, 1 patient (1%) required TTVP because of complete heart block and received a PPM. Five of the 83 (6%) patients were inappropriately paced, and 1 patient (1%) had ventricular fibrillation, likely secondary to TTVP. A total of 34 patients (41%) underwent electrophysiology study during hospitalization, with 4 of 83 (5%) subsequently receiving a PPM. One (1%) patient died during hospitalization, and 9 patients were lost to follow-up because of the COVID-19 pandemic. Of the remaining 73 patients with a 30-day follow-up, NLBBB had resolved in 36 (49%) at 30 days, and 2 (3%) were readmitted with complete heart block and received PPM. In conclusion, in patients with TAVI who develop NLBBB, temporary pacing is rarely necessary, may carry additional risks to the patient, and prolong hospitalization time.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Marca-Passo Artificial / Bloqueio Atrioventricular / Substituição da Valva Aórtica Transcateter / COVID-19 Tipo de estudo: Etiology_studies / Observational_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Marca-Passo Artificial / Bloqueio Atrioventricular / Substituição da Valva Aórtica Transcateter / COVID-19 Tipo de estudo: Etiology_studies / Observational_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article