Enhanced electrochemical detection of iodide at a reduced graphene oxide-modified carbon electrode in iodized salts.
Jamilan, Mohd Azerulazree; Abdullah, Jaafar; Alang Ahmad, Shahrul Ainliah; Md Noh, Mohd Fairulnizal.
Afiliação
  • Jamilan MA; Nutrition, Metabolism and Cardiovascular Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, No. 1, Jalan Setia Murni U13/52, Setia Alam, 40170 Shah Alam, Selangor D.E., Malaysia; Department of Chemistry, Faculty of Science, Universiti Putra M
  • Abdullah J; Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor D.E., Malaysia; Institute of Nanoscience and Nanotechnology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor D.E., Malaysia. Electronic address: jafar@upm.edu.my.
  • Alang Ahmad SA; Department of Chemistry, Faculty of Science, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor D.E., Malaysia; Institute of Nanoscience and Nanotechnology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor D.E., Malaysia.
  • Md Noh MF; Nutrition, Metabolism and Cardiovascular Research Centre, Institute for Medical Research, National Institutes of Health, Ministry of Health Malaysia, No. 1, Jalan Setia Murni U13/52, Setia Alam, 40170 Shah Alam, Selangor D.E., Malaysia.
Food Chem ; 393: 133382, 2022 Nov 01.
Article em En | MEDLINE | ID: mdl-35667176
ABSTRACT
In this study, enhancement of electrochemical performance of electrochemically reduced graphene oxide (ERGO) on a screen-printed carbon electrode (SPCE) (ERGO/SPCE) coupled with ion-pairing (cetyltrimethylammonium bromide, CTAB) for the determination of iodide in table salt has been described. The electrode modification of ERGO/SPCE was conducted using cyclic voltammetric (CV) scanning in the potential range of 1.3-0.4 V for 50 cycles after the drop-casting of graphene oxide (GO) suspension on the SPCE. It was found that the electro-active surface area of ERGO/SPCE was increased by 1.5-fold compared to the bare SPCE. ERGO/SPCE sensor displays linearity towards iodide in the concentration range from 0.020 to 1.0 mg/L (sensitivity = 5.40 µA(mg/L)-1, R2 = 0.9906) with the limit of detection (LOD) and limit of quantitation (LOQ) of 0.070 mg/L and 0.21 mg/L, respectively. The comparison between polarography and ERGO/SPCE sensor was in good agreement.