Your browser doesn't support javascript.
loading
Ultra-Sensitive Fluorimetric Method for the First Estimation of Vonoprazan in Real Human Plasma and Content Uniformity Test.
Saraya, Roshdy E; Hassan, Yasser F; Eltukhi, Walid E; Salman, Baher I.
Afiliação
  • Saraya RE; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Port Said University, Port Said, 42511, Egypt.
  • Hassan YF; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University-Assiut Branch, Assiut, 71524, Egypt.
  • Eltukhi WE; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University-Assiut Branch, Assiut, 71524, Egypt.
  • Salman BI; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Al-Azhar University-Assiut Branch, Assiut, 71524, Egypt. bahersalman@azhar.edu.eg.
J Fluoresc ; 32(5): 1725-1732, 2022 Sep.
Article em En | MEDLINE | ID: mdl-35670919
ABSTRACT
Vonoprazan (VON) has been approved recently via US-FDA in 2015 as the first in class of potassium competitive acid blocker group. VON is used for management of GIT ulcer, reflux esophagitis and for eradication of Helicobacter pylori. So, the first spectrofluorimetric method was developed for estimation of VON in real human plasma and content uniformity test. The fluorimetric methodology based on reaction of secondary amine group in VON with benzofurazan (0.05% w/v NBD-Cl) reagent as nucleophilic substitution reaction in alkaline medium (0.1 M borate buffer pH 8.2) to produce highly fluorescent product measure at 530 nm after excitation at 465 nm. The linear calibration range was found 15 to 200 ng mL-1 with lower limit of quantitation (LOQ) equal to 8.57 ng mL-1. The method was successfully applied for estimation of VON in pharmacokinetic (PK) and content uniformity studies. The maximum plasma concentration was found to be (Cmax) 71.03 ng mL-1 after maximum time (tmax) equal to 1.5 ± 0.15 h. The presented strategy also applied to ensure concentration of drug in each tablet using content uniformity test with high percent of recovery 100.05 ± 0.66. The proposed method was established for clinical laboratories and therapeutic drug monitoring studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pirróis / Sulfonamidas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pirróis / Sulfonamidas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article