Your browser doesn't support javascript.
loading
[Study on determination of 2-thioxothiazolidine-4-carboxylic Acid in urine by high performance liquid chromatography].
Jiang, J F; Song, W L; Liu, Y P; Liu, J P; Wang, M.
Afiliação
  • Jiang JF; Department of Health Laboratory Technology, Wuhan Prevention and Treatment Center for Occupational Disease, Wuhan 430015, China.
  • Song WL; Department of Health Laboratory Technology, Wuhan Prevention and Treatment Center for Occupational Disease, Wuhan 430015, China.
  • Liu YP; Department of Health Laboratory Technology, Wuhan Prevention and Treatment Center for Occupational Disease, Wuhan 430015, China.
  • Liu JP; Department of Health Laboratory Technology, Wuhan Prevention and Treatment Center for Occupational Disease, Wuhan 430015, China.
  • Wang M; Department of Health Laboratory Technology, Wuhan Prevention and Treatment Center for Occupational Disease, Wuhan 430015, China.
Article em Zh | MEDLINE | ID: mdl-35680582
ABSTRACT

Objective:

To establish a high performance liquid chromatography method for the determination of 2-thioxothiazolidine-4-carboxylic acid (TTCA) in urine.

Methods:

After acidification with hydrochloric acid, TTCA in urine was first extracted by ethyl acetate with excessive sodium chloride, then gradient separated by a symmetry C18 column and then detected by a diode array detector. The quantification was based on a working curve of external standard method.

Results:

The linear relationship of TTCA in urine was good in the range of 0.03-10.00 mg/L, and the correlation coefficient was 0.9999. The detection limit and minimum quantitative concentration of TTCA in urine were 0.008 mg/L and 0.027 mg/L. The intra-assay precision of the method was 0.9%-1.4%, the inter-assay precision was 1.3%-3.5%, and the average recovery was 85.0%-92.7% while the concentrations of TTCA in urine was 0.8, 2.0 and 8.0 mg/L, respectively (n=6) .

Conclusion:

The gradient elution high performance liquid chromatography method has simple operation and high sensitivity, and it is suitable for the determination of TTCA on a low level in urine for occupational workers exposure to carbon disulfide.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tiazóis / Dissulfeto de Carbono Limite: Humans Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tiazóis / Dissulfeto de Carbono Limite: Humans Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article