Your browser doesn't support javascript.
loading
Patient-Derived Training Simulator for Image-Guided Adaptive Brachytherapy of Locally Advanced Cervical Cancers: Development and Initial Use.
Tomizawa, Kento; Oike, Takahiro; Ando, Ken; Irie, Daisuke; Sakai, Makoto; Shimada, Hirofumi; Ohno, Tatsuya.
Afiliação
  • Tomizawa K; Department of Radiation Oncology, Gunma University Graduate School of Medicine, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
  • Oike T; Department of Radiation Oncology, Gunma University Graduate School of Medicine, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
  • Ando K; Gunma University Heavy Ion Medical Center, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
  • Irie D; Department of Radiation Oncology, Gunma University Graduate School of Medicine, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
  • Sakai M; Department of Radiation Oncology, Gunma University Graduate School of Medicine, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
  • Shimada H; Gunma University Heavy Ion Medical Center, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
  • Ohno T; Gunma University Heavy Ion Medical Center, 3-39-22 Showa-machi, Maebashi 371-8511, Gunma, Japan.
J Clin Med ; 11(11)2022 May 30.
Article em En | MEDLINE | ID: mdl-35683490
ABSTRACT
Image-guided adaptive brachytherapy (IGABT) using intracavitary and interstitial (IC/IS) techniques plays a pivotal role in definitive radiotherapy for locally advanced cervical cancers. However, the training opportunities for interstitial needle application are limited, preventing this technique from becoming widespread. This study aimed to develop a training simulator for IC/IS brachytherapy. The simulator consists of a soft silicone tumor phantom and acrylic tube mimicking the vagina; it has high visibility because of translucent materials and is compatible with computed tomography (CT) and magnetic resonance imaging (MRI). A patient harboring a typical bulky and irregular-shaped cervical tumor was selected from 495 in-house IGABT-treated candidates, and a tumor phantom (68 × 49 × 45 mm) modeled on this patient was produced from three-dimensional real-scale measurements of the MRI-based high-risk clinical target volume at first brachytherapy. In trial use by two physicians with different levels of IGABT skills, a Fletcher-Suit Asian Pacific applicator, and a Venezia applicator with interstitial needles were nicely applied to the simulator, facilitating successful creation of CT-based treatment plans consistent with clinical practice. Thus, the training simulator can be useful for the training of IC/IS brachytherapy, and warrants further research employing a greater number of phantoms and practitioners to verify its educational value.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article