Your browser doesn't support javascript.
loading
Single-type reporter multiplexing with A single droplet through bead-based digital microfluidics.
Lee, Meng-Shiue; Chang, Yen-Chia; Huang, Hong-Yuan; Hsu, Wensyang.
Afiliação
  • Lee MS; Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010 Taiwan; Institute of Pharmacology, National Yang Ming Chiao Tung University, Taipei 11221, Taiwan.
  • Chang YC; Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010 Taiwan.
  • Huang HY; Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan; Department of Obstetrics and Gynecology, Chang Gung University College of Medicine, Tao-Yuan, Taiwan.
  • Hsu W; Department of Mechanical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010 Taiwan. Electronic address: whsu@nycu.edu.tw.
J Pharm Biomed Anal ; 219: 114877, 2022 Sep 20.
Article em En | MEDLINE | ID: mdl-35717702
ABSTRACT
With the limited sample volume, the droplet-based microfluidic becomes attractive in biomedical diagnosis, especially for measuring multiple analytes. Usually, for multiplexing by parallel processing, a larger sample volume is required. In our previous study, simultaneously detecting two analytes from a single droplet was first achieved by measuring different fluorescence wavelengths for different analytes. However, the number of detectable analytes could be limited by the spectral resolution of fluorescence. Here a different approach is proposed for multiplexing by sharing a single droplet in multiple sub-assays. Therefore, only a single-type reporter, i.e., the fluorescence with the same wavelength, is needed for detection of different analytes from a single sample droplet, called single-type reporter multiplexing (STRM). The standard curves of two analytes, human IL-1ß and human TNF-α, are demonstrated. The required sample volume for one measurement is only 520 nL; the total duration of the on-chip process is less than 50 min. The limits of detection (LOD) of human IL-1ß and human TNF-α are about 1.14 and 0.97 pg/mL, respectively. It is shown that the proposed bead-based digital microfluidic immunoassay can achieve multiple analytes detection with low LOD from a single sample droplet using the single-type reporter, which has never been achieved before.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fator de Necrose Tumoral alfa / Microfluídica Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fator de Necrose Tumoral alfa / Microfluídica Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article