Your browser doesn't support javascript.
loading
Successful retrieval of embolised Occlutech atrial septal defect occluder from descending aorta in a 4-year-old child using a "mother and child" technique: a case report and literature review.
Salam, Abdul; Yates, Robert; Khambadkone, Sachin.
Afiliação
  • Salam A; University College London, Institute of Cardiovascular Science, London, UK.
  • Yates R; Great Ormond Street Hospital for Children, London, UK.
  • Khambadkone S; University College London, Institute of Cardiovascular Science, London, UK.
Cardiol Young ; 33(2): 309-312, 2023 Feb.
Article em En | MEDLINE | ID: mdl-35725276
A 9 mm Occlutech septal occluder Flex II device was retrieved in a 4-year-old 22 kg child; A 6 Fr Cook® Flexor sheath (child) was inserted into a 9 Fr Occlutech® ASD Delivery Set (mother). Once the tip of the smaller sheath was close to the device, a 4 Fr right Judkins catheter was introduced with a snare. The right atrial hub was captured and withdrawn to the level of the 6 Fr sheath which was then withdrawn into the 9 Fr sheath before being removed completely. The "mother and child" technique offers a greater likelihood of slenderising and retrieving embolised devices.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivo para Oclusão Septal / Comunicação Interatrial Limite: Child, preschool / Female / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivo para Oclusão Septal / Comunicação Interatrial Limite: Child, preschool / Female / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article