Path-Planning System for Radioisotope Identification Devices Using 4π Gamma Imaging Based on Random Forest Analysis.
Tomita, Hideki; Hara, Shintaro; Mukai, Atsushi; Yamagishi, Keita; Ebi, Hidetake; Shimazoe, Kenji; Tamura, Yusuke; Woo, Hanwool; Takahashi, Hiroyuki; Asama, Hajime; Ishida, Fumihiko; Takada, Eiji; Kawarabayashi, Jun; Tanabe, Kosuke; Kamada, Kei.
Afiliação
  • Tomita H; Department of Energy Engineering, Nagoya University, Nagoya 464-8603, Japan.
  • Hara S; Department of Energy Engineering, Nagoya University, Nagoya 464-8603, Japan.
  • Mukai A; Department of Energy Engineering, Nagoya University, Nagoya 464-8603, Japan.
  • Yamagishi K; Department of Energy Engineering, Nagoya University, Nagoya 464-8603, Japan.
  • Ebi H; Department of Energy Engineering, Nagoya University, Nagoya 464-8603, Japan.
  • Shimazoe K; Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo 113-8656, Japan.
  • Tamura Y; Department of Robotics, Tohoku University, Sendai 980-8579, Japan.
  • Woo H; Department of Mechanical Systems Engineering, Kogakuin University, Hachioji 192-0015, Japan.
  • Takahashi H; Department of Nuclear Engineering and Management, The University of Tokyo, Tokyo 113-8656, Japan.
  • Asama H; Department of Precision Engineering, The University of Tokyo, Tokyo 113-8656, Japan.
  • Ishida F; National Institute of Technology, Toyama College, Toyama-shi 939-8630, Japan.
  • Takada E; National Institute of Technology, Toyama College, Toyama-shi 939-8630, Japan.
  • Kawarabayashi J; Department of Nuclear Safety Engineering, Tokyo City University, Tokyo 158-8557, Japan.
  • Tanabe K; National Research Institute of Police Science, Chiba 277-0882, Japan.
  • Kamada K; Institute of Engineering Innovation, Tohoku University, Sendai 980-8579, Japan.
Sensors (Basel) ; 22(12)2022 Jun 07.
Article em En | MEDLINE | ID: mdl-35746105
We developed a path-planning system for radiation source identification devices using 4π gamma imaging. The estimated source location and activity were calculated by an integrated simulation model by using 4π gamma images at multiple measurement positions. Using these calculated values, a prediction model to estimate the probability of identification at the next measurement position was created by via random forest analysis. The path-planning system based on the prediction model was verified by integrated simulation and experiment for a 137Cs point source. The results showed that 137Cs point sources were identified using the few measurement positions suggested by the path-planning system.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Diagnóstico por Imagem Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Diagnóstico por Imagem Tipo de estudo: Clinical_trials / Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article