Your browser doesn't support javascript.
loading
Usefulness of Leucocyte Cell Population Data by Sysmex XN1000 Hematology Analyzer in Rapid Identification of Acute Leukemia.
Mishra, Shruti; Chhabra, Gaurav; Padhi, Somanath; Mohapatra, Sonali; Panigrahi, Ashutosh; Sable, Mukund Namdev; Das, Prabodha Kumar.
Afiliação
  • Mishra S; Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Bhubaneswar, India.
  • Chhabra G; Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Bhubaneswar, India.
  • Padhi S; Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Bhubaneswar, India.
  • Mohapatra S; Department of Medical Oncology/Hematology, All India Institute of Medical Sciences, Bhubaneswar, India.
  • Panigrahi A; Department of Medical Oncology/Hematology, All India Institute of Medical Sciences, Bhubaneswar, India.
  • Sable MN; Department of Pathology and Laboratory Medicine, All India Institute of Medical Sciences, Bhubaneswar, India.
  • Das PK; Department of Medical Oncology/Hematology, All India Institute of Medical Sciences, Bhubaneswar, India.
Indian J Hematol Blood Transfus ; 38(3): 499-507, 2022 Jul.
Article em En | MEDLINE | ID: mdl-35747581
ABSTRACT
Leukocyte cell population data (CPD) generated by hematology auto analyzers are reported to be useful in screening of sepsis patients. However, there is a paucity of literature highlighting the utility of CPD in screening of acute leukemias (AL). Leucocyte CPD obtained by Sysmex XN1000 hematology analyzer from 210 cases of ALs [22 acute promyelocytic leukemia (APL), 79 non-APL acute myeloid leukemia (non-APL-AML) and 109 acute lymphoblastic leukemia (ALL)] were compared with 100 healthy and 52 reactive controls. Receiver operator curves were drawn to determine the cut-off values of individual parameters. The regression equations combining the best parameters were then formulated to calculate a cut-off value for discrimination among AL subgroups and controls. Acute leukemias showed significant differences (p < 0.05) in various CPD parameters compared to control subjects. A combination of best CPD parameters discriminated ALs from healthy controls (cut off; 0.443, sensitivity of 94% and specificity of 91%), ALs from reactive controls (cut off; 0.576, sensitivity; 97%, specificity; 92%), APL from non-APL-AML (cut off; 0.174, sensitivity of 91% and specificity of 67%), and AML from ALL (cut off; 1.338, sensitivity; 86.1%, specificity; 75%). The CPD from Sysmex XN 1000 analyzer could be a useful tool in screening and lineage characterization of acute leukemias; particularly at centers where high-end technical expertise is still not available. Supplementary Information The online version contains supplementary material available at 10.1007/s12288-021-01488-9.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article