Your browser doesn't support javascript.
loading
The healing response of LAMax LAAC™ left atrial appendage occluder in a canine model: the potential influence of the implantation technique on the healing response.
Wu, Xiaoxia; Ma, Dongxing; Wan, Tao; Meng, Yuezhi; Chen, Yilong; Shen, Yejia; Huang, Wei.
Afiliação
  • Wu X; Department of Cardiology, The Third Medical Center, Chinese PLA(People's Liberation Army) General Hospital, 69 Yongding Road, Hai Dian District, Beijing, 100039, China.
  • Ma D; Department of Cardiology, The Third Medical Center, Chinese PLA(People's Liberation Army) General Hospital, 69 Yongding Road, Hai Dian District, Beijing, 100039, China. madongxing2004@126.com.
  • Wan T; Faculty of Hepato-Pancreato-Biliary Surgery, Chinese PLA General Hospital, Beijing, China.
  • Meng Y; Department of Cardiology, The Third Medical Center, Chinese PLA(People's Liberation Army) General Hospital, 69 Yongding Road, Hai Dian District, Beijing, 100039, China.
  • Chen Y; ShenZhen KYD Biomedical Technology Co. Ltd., Shenzhen, China.
  • Shen Y; ShenZhen Cardiovascular Engineering Laboratory of Drug and Device Development, Shenzhen, China.
  • Huang W; Department of Cardiology, The Third Medical Center, Chinese PLA(People's Liberation Army) General Hospital, 69 Yongding Road, Hai Dian District, Beijing, 100039, China.
BMC Cardiovasc Disord ; 22(1): 291, 2022 06 27.
Article em En | MEDLINE | ID: mdl-35761168
BACKGROUND: Device-associated thrombus are potential causes for thromboembolic events post left atrial appendage closure (LAAC), and correlated with the complete endothelialization of the device surface. Our aim was to evaluate the endothelialization of LAMax LAAC™ occluder surface and analyze the potential influence of the implantation technique on the healing response. METHODS: A total of 29 healthy dogs (28.0 ± 3.7 kg) were implanted with the devices successfully after ensuring COVER signs was met (Concavity of the disc, Oversizing by 20-50%, Verifying position, Ensuring stability, Residual flow < 5 mm by transesophageal echocardiographic (TEE) examination), and sacrificed at < 24 h, 1-, 2-, 3-, and 6-months. Gross examinations were conducted to evaluate healing response. RESULTS: The mean diameters of LAA orifice measured by angiography and TEE were 19.0 ± 2.9 mm and 16.6 ± 2.9 mm (P < 0.05), respectively. TEE found that the discs in 18 dogs (62.1%) were completely pulled into the LAA with concavity and in 11 dogs incompletely pulled into the LAA with suboptimally concavity, while 5 of them had residual flow. Gross examinations showed that the complete endothelialization on the device surface with concaved disc was found at 1-month after LAAC. Microscopic examinations confirmed complete healing on the device with optimal closure effect. CONCLUSIONS: The good healing response and the optimal closure effect were observed using the LAMax device in a canine model by following the COVER implantation technique.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Apêndice Atrial / Dispositivo para Oclusão Septal Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Apêndice Atrial / Dispositivo para Oclusão Septal Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article