Your browser doesn't support javascript.
loading
Transit-guided radiation therapy: proof of concept of an on-line technique for correcting position errors using transit portal images.
Latorre-Musoll, Artur; Delgado-Tapia, Paula; Gisbert, María Lizondo; Sala, Núria Jornet; Sempau, Josep.
Afiliação
  • Latorre-Musoll A; Servei d'Oncologia Radioteràpia (ICMHO), Hospital Clínic de Barcelona, Barcelona, Spain.
  • Delgado-Tapia P; Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Marqués de Valdecilla, Santander, Spain.
  • Gisbert ML; Servicio de Oncología Radioterápica, Consorci Sanitari de Terrassa, Terrassa, Spain.
  • Sala NJ; Servei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain.
  • Sempau J; Universitat Politècnica de Catalunya, Barcelona, Spain.
Phys Med Biol ; 67(15)2022 07 29.
Article em En | MEDLINE | ID: mdl-35767982
Objective.Transitin vivodosimetry methods monitor that the dose distribution is delivered as planned. However, they have a limited ability to identify and to quantify the cause of a given disagreement, especially those caused by position errors. This paper describes a proof of concept of a simplein vivotechnique to infer a position error from a transit portal image (TPI).Approach.For a given treatment field, the impact of a position error is modeled as a perturbation of the corresponding reference (unperturbed) TPI. The perturbation model determines the patient translation, described by a shift vector, by comparing a givenin vivoTPI to the corresponding reference TPI. Patient rotations can also be determined by applying this formalism to independent regions of interest over the patient. Eight treatment plans have been delivered to an anthropomorphic phantom under a large set of couch shifts (<15 mm) and rotations (<10°) to experimentally validate this technique, which we have named Transit-Guided Radiation Therapy (TGRT).Main results.The root mean squared error (RMSE) between the determined and the true shift magnitudes was 1.0/2.4/4.9 mm for true shifts ranging between 0-5/5-10/10-15 mm, respectively. The angular accuracy of the determined shift directions was 12° ± 14°. The RMSE between the determined and the true rotations was 0.5°. The TGRT technique decoupled translations and rotations satisfactorily. In 96% of the cases, the TGRT technique decreased the existing position error. The detection threshold of the TGRT technique was around 1 mm and it was nearly independent of the tumor site, delivery technique, beam energy or patient thickness.Significance.TGRT is a promising technique that not only provides reliable determinations of the position errors without increasing the required equipment, acquisition time or patient dose, but it also adds on-line correction capabilities to existing methods currently using TPIs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Equipamentos e Provisões Elétricas Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Equipamentos e Provisões Elétricas Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article