Your browser doesn't support javascript.
loading
High-Throughput Nano-DESI Mass Spectrometry Imaging of Biological Tissues Using an Integrated Microfluidic Probe.
Li, Xiangtang; Hu, Hang; Yin, Ruichuan; Li, Yingju; Sun, Xiaofei; Dey, Sudhansu K; Laskin, Julia.
Afiliação
  • Li X; Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
  • Hu H; Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
  • Yin R; Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
  • Li Y; Division of Reproductive Sciences, Cincinnati Children's Hospital Medical Centre and Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio 45229, United States.
  • Sun X; Division of Reproductive Sciences, Cincinnati Children's Hospital Medical Centre and Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio 45229, United States.
  • Dey SK; Division of Reproductive Sciences, Cincinnati Children's Hospital Medical Centre and Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, Ohio 45229, United States.
  • Laskin J; Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.
Anal Chem ; 94(27): 9690-9696, 2022 07 12.
Article em En | MEDLINE | ID: mdl-35770488
ABSTRACT
Nanospray desorption electrospray mass spectrometry imaging (nano-DESI MSI) enables quantitative mapping of hundreds of molecules in biological samples with minimal sample pretreatment. We have recently developed an integrated microfluidic probe (iMFP) for nano-DESI MSI. Herein, we describe an improved design of the iMFP for the high-throughput imaging of tissue sections. We increased the dimensions of the primary and spray channels and optimized the spray voltage and solvent flow rate to obtain a stable operation of the iMFP at both low and high scan rates. We observe that the sensitivity, molecular coverage, and spatial resolution obtained using the iMFP do not change to a significant extent as the scan rate increases. Using a scan rate of 0.4 mm/s, we obtained high-quality images of mouse uterine tissue sections (scan area 3.2 mm × 2.3 mm) in only 9.5 min and of mouse brain tissue (scan area 7.0 mm × 5.4 mm) in 21.7 min, which corresponds to a 10-15-fold improvement in the experimental throughput. We have also developed a quantitative metric for evaluating the quality of ion images obtained at different scan rates. Using this metric, we demonstrate that the quality of nano-DESI MSI data does not degrade substantially with an increase in the scan rate. The ability to image biological tissues with high throughput using iMFP-based nano-DESI MSI will substantially speed up tissue mapping efforts.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray / Microfluídica Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas por Ionização por Electrospray / Microfluídica Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article