Your browser doesn't support javascript.
loading
Outcomes of the Gore Excluder Iliac Branch Endoprosthesis for Japanese Patients With Aortoiliac Aneurysms: A Study Based on J-Preserve Registry.
Ogawa, Yukihisa; Fujimura, Naoki; Yamaguchi, Masato; Banno, Hiroshi; Furuyama, Tadashi; Yamaoka, Terutoshi; Sumi, Makoto; Fukuda, Tetsuya; Morikage, Noriyasu; Sohgawa, Etsuji; Onitsuka, Seiji; Nishimaki, Hiroshi; Ichihashi, Shigeo.
Afiliação
  • Ogawa Y; Department of Radiology, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Fujimura N; Division of Vascular Surgery, Saiseikai Central Hospital, Tokyo, Japan.
  • Yamaguchi M; Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
  • Banno H; Division of Vascular and Endovascular Surgery, Department of Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan.
  • Furuyama T; Department of Surgery and Science, Kyushu University Graduate School of Medicine, Fukuoka, Japan.
  • Yamaoka T; Department of Vascular Surgery, Matsuyama Red Cross Hospital, Matsuyama, Japan.
  • Sumi M; Department of Vascular Surgery, Saitama Cardiovascular and Respiratory Center, Kumagaya, Japan.
  • Fukuda T; Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Japan.
  • Morikage N; Division of Vascular Surgery, Department of Surgery and Clinical Science, Yamaguchi University, Ube, Japan.
  • Sohgawa E; Department of Diagnostic and Interventional Radiology, Osaka City University Graduate School of Medicine, Osaka, Japan.
  • Onitsuka S; Department of Surgery, Kurume University School of Medicine, Kurume, Japan.
  • Nishimaki H; Department of Cardiovascular Surgery, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Ichihashi S; Department of Radiology, Nara Medical University, Kashihara, Japan.
J Endovasc Ther ; : 15266028221109477, 2022 Jul 11.
Article em En | MEDLINE | ID: mdl-35815459
ABSTRACT

PURPOSE:

To evaluate the clinical utility of the Gore Excluder iliac branch endoprosthesis (IBE) for Japanese patients with aortoiliac aneurysms. MATERIALS AND

METHODS:

This was a multicenter retrospective cohort study (J-Preserve Registry). Patients undergoing endovascular aortic repair using the Gore Excluder IBE for aortoiliac aneurysms between August 2017 and June 2020 were enrolled. Data pertaining to the baseline and anatomical characteristics, technical details, and clinical outcomes were collected from each institution. The primary endpoints were technical success, IBE-related complications, and reinterventions. Secondary endpoints were mortality, aneurysm size change, and reintervention during follow-up. Technical success was defined as accurate deployment of the IBE without type Ib, Ic, or III endoleaks on the IBE sides on completion angiography. A change in aneurysm size of 5 mm or more was taken to be a significant change.

RESULTS:

We included 141 patients with 151 IBE implantations. Sixty-five IBE implantations (43.0%) had at least one instruction for use violation. Twenty-two patients (15.6%) required internal iliac artery (IIA) embolization for external iliac artery extension on the contralateral side. Of 151 IBE implantations, 19 exhibited IIA branch landing zones due to IIA aneurysms. Mean maximum and proximal common iliac artery (CIA) diameters were 32.9±9.9 mm and 20.5±6.9 mm, respectively. The mean CIA length was 59.1±17.1 mm. The IIA landing diameter and length were 9.0±2.3 mm and 33.8±14.6 mm. The overall technical success rate was 96.7%. There were no significant differences in IBE-related complications (2.3% vs 5.3%, p=0.86) or IBE-related reinterventions (1.5% vs 5.3%, p=0.33) between the IIA trunk and IIA branch landing groups. The mean follow-up period was 635±341 days. The all-cause mortality rate was 5.0%. There were no aneurysm-related deaths or ruptures during the follow-up. Most patients (95.7%) had sac stability or shrinkage.

CONCLUSION:

The Gore Excluder IBE was safe and effective for Japanese patients in the midterm. Extending the IIA device into the distal branches of the IIA was acceptable, which may permit extending indications for endovascular aortic aneurysm repair of aortoiliac aneurysms to more complex lesions. CLINICAL IMPACT This study suggests clinical benefits of the Gore Excluder IBE for Japanese patients, despite 43% of the IBE implantations having at least one IFU violation.