Your browser doesn't support javascript.
loading
Survival analysis up to 7 years of 621 zirconia monolithic single crowns with feather-edge margins fabricated with a cast-free workflow starting from intraoral scans: A multicentric retrospective study.
Valenti, Marco; Valenti, Alessandro; Schmitz, Johannes H; Cortellini, Davide; Canale, Angelo.
Afiliação
  • Valenti M; Private practice, Pordenone, Italy. Electronic address: marco@studiodentisticovalenti.com.
  • Valenti A; Private practice, Pordenone, Italy.
  • Schmitz JH; Private practice, Milan, Italy.
  • Cortellini D; Private practice, Riccione, Italy.
  • Canale A; Dental Lab Owner, Rimini, Italy.
J Prosthet Dent ; 129(1): 76-82, 2023 Jan.
Article em En | MEDLINE | ID: mdl-35850872
ABSTRACT
STATEMENT OF

PROBLEM:

Clinical studies on the fabrication of monolithic zirconia restorations with a feather-edge tooth preparation from digital scans and a cast-free fully digital workflow are lacking.

PURPOSE:

The purpose of this retrospective multicentric study in private practices was to evaluate the outcomes of monolithic zirconia crowns fabricated with feather-edge margins and a cast-free approach. MATERIAL AND

METHODS:

A total of 621 teeth were prepared with feather-edge margins and restored with monolithic zirconia crowns fabricated with a fully digital cast-free workflow. Data were analyzed by using the Kaplan-Meier test and descriptive statistics. The clinical evaluation adopted the California Dental Association-modified criteria after recalling all patients between April and July 2021.

RESULTS:

The clinical survival of 619 of 621 crowns, including recemented crowns placed in 427 patients (217 men, 220 women) over 5 years (2014 to 2019 with crowns in service between 12 and 85 months), was analyzed. The 2 excluded crowns were delivered to patients who dropped out of the study. Of the 619 crowns, 5 failed during the follow-up period 4 teeth were extracted because of fracture and 1 restoration fractured. No other technical or biological failures were observed. The mean overall survival time was 84.4 months (standard error, 0.255; 95% confidence interval for the mean, 83.92 to 84.92). The overall survival probability was 99.1% up to 85 months.

CONCLUSIONS:

The clinical outcomes of the monolithic zirconia crowns with feather-edge margins evaluated were comparable with outcomes reported using other margin designs and materials.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Zircônio / Planejamento de Prótese Dentária Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Zircônio / Planejamento de Prótese Dentária Tipo de estudo: Clinical_trials / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article