Your browser doesn't support javascript.
loading
Accuracy of a chairside, fused deposition modeling three-dimensional-printed, single tooth surgical guide for implant placement: A randomized controlled clinical trial.
Sun, Yao; Ding, Qian; Yuan, Fusong; Zhang, Lei; Sun, Yuchun; Xie, Qiufei.
Afiliação
  • Sun Y; Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, China.
  • Ding Q; Department of Prosthodontics, The Third Clinic of Peking University School and Hospital of Stomatology, Beijing, China.
  • Yuan F; Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, China.
  • Zhang L; Faculty of Prosthodontics, Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beiji
  • Sun Y; Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, China.
  • Xie Q; Faculty of Prosthodontics, Center of Digital Dentistry, Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Center of Engineering and Technology for Digital Dentistry of Ministry of Health, Beiji
Clin Oral Implants Res ; 33(10): 1000-1009, 2022 Oct.
Article em En | MEDLINE | ID: mdl-35852859
PURPOSE: To compare the accuracy of chairside, fused deposition modeling (FDM) three-dimensional (3D)-printed surgical guides with that of stereolithographic guides for implant placement in single edentulous sites within a clinical setting. MATERIALS AND METHODS: A total of 28 participants with 30 single posterior edentulous sites were included. The sites were randomized into a FDM 3D-printed surgical guide group (test) or stereolithographic guide group (control) of equal size (n = 15). In both groups, digital implant planning was performed using data from cone beam-computed tomography and intraoral scans. The test group's surgical guides were fabricated using a chairside, FDM 3D-printer; those in the control group were fabricated using a light-curing 3D-printer. Postoperative intraoral scans were used to obtain the 3D position of the implants. Compared to preoperative design, the angular, 3D, mesiodistal, buccolingual and apicocoronal deviations at the implant shoulder and apex were recorded. RESULTS: The workflow for the design and chairside fabrication of implant guides was established. The mean angular deviations of the test and control group were (4.23 ± 2.38) ° and (4.13 ± 2.42) ° (p > .05), respectively. The respective 3D deviations at the implant shoulder were (0.70 ± 0.44) mm and (0.55 ± 0.27) mm (p > .05); those at the implant apex were (1.25 ± 0.61) mm and (1.11 ± 0.54) mm (p > .05). The mesiodistal, buccolingual, and apicocoronal deviations at the implant shoulder and apex did not significantly differ between the groups (p > .05). CONCLUSIONS: Implants for single posterior edentulous spaces were placed as accurately with the test guide as with the control. Further research under more complex situations involving multiple missing teeth is needed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Boca Edêntula / Cirurgia Assistida por Computador Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Dentários / Boca Edêntula / Cirurgia Assistida por Computador Tipo de estudo: Clinical_trials Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article