ABSTRACT

PURPOSE:

To demonstrate the feasibility of Octafen technique, a novel endovascular configuration for the treatment of thoracoabdominal aortic aneurysms (TAAA). TECHNIQUE Two patients with complex TAAA and high surgical risk were treated with Octafen endograft configuration in a hybrid operating room with computed tomography (CT)-fluoroscopy image fusion guidance, using 3D-3D fusion techniques to facilitate procedural success. The procedure is a modification of the previously-described Octopus technique for endovascular repair of TAAA. The main advantage of this technique is the ability to use devices to repair a TAAA with the combination of off-the-shelf and noninvestigational custom-made devices. The devices used are readily available to most practicing vascular surgeons, which provides an alternative treatment in case of limited access to investigational devices, in time-sensitive cases, and in patients with limited functional capacity who cannot undergo open repair. In the modification described herein, we use a combination of standard bifurcated endovascular aneurysm repair (EVAR) devices (Excluder; W.L. Gore & Associates, Flagstaff, Arizona) in combination with a 2-vessel renal fenestrated device (Z-Fen; Cook Medical, Bloomington, Indiana). The article describes a step-by-step approach to this technique to elucidate pitfalls, benefits, and advantages.

CONCLUSION:

The Octafen technique might offer an alternative option for thoracoabdominal aneurysm treatment circumventing the need for access to custom-made, investigational devices. CLINICAL IMPACT In this manuscript, we describe a technique for endovascular repair of thoraco-abdominal aortic aneurysms that involves the combination of off-the-shelf and non-investigational, custom-made devices. The 'Octafen' technique provides a treatment alternative in case of limited access to investigational devices and can be adjusted according to patient anatomy.