Your browser doesn't support javascript.
loading
Multimodal Registration for Image-Guided EBUS Bronchoscopy.
Zang, Xiaonan; Zhao, Wennan; Toth, Jennifer; Bascom, Rebecca; Higgins, William.
Afiliação
  • Zang X; School of Electrical Engineering and Computer Science, Penn State University, State College, PA 16802, USA.
  • Zhao W; School of Electrical Engineering and Computer Science, Penn State University, State College, PA 16802, USA.
  • Toth J; Penn State Milton S. Hershey Medical Center, Hershey, PA 17033, USA.
  • Bascom R; Penn State Milton S. Hershey Medical Center, Hershey, PA 17033, USA.
  • Higgins W; School of Electrical Engineering and Computer Science, Penn State University, State College, PA 16802, USA.
J Imaging ; 8(7)2022 Jul 08.
Article em En | MEDLINE | ID: mdl-35877633
ABSTRACT
The state-of-the-art procedure for examining the lymph nodes in a lung cancer patient involves using an endobronchial ultrasound (EBUS) bronchoscope. The EBUS bronchoscope integrates two modalities into one device (1) videobronchoscopy, which gives video images of the airway walls; and (2) convex-probe EBUS, which gives 2D fan-shaped views of extraluminal structures situated outside the airways. During the procedure, the physician first employs videobronchoscopy to navigate the device through the airways. Next, upon reaching a given node's approximate vicinity, the physician probes the airway walls using EBUS to localize the node. Due to the fact that lymph nodes lie beyond the airways, EBUS is essential for confirming a node's location. Unfortunately, it is well-documented that EBUS is difficult to use. In addition, while new image-guided bronchoscopy systems provide effective guidance for videobronchoscopic navigation, they offer no assistance for guiding EBUS localization. We propose a method for registering a patient's chest CT scan to live surgical EBUS views, thereby facilitating accurate image-guided EBUS bronchoscopy. The method entails an optimization process that registers CT-based virtual EBUS views to live EBUS probe views. Results using lung cancer patient data show that the method correctly registered 28/28 (100%) lymph nodes scanned by EBUS, with a mean registration time of 3.4 s. In addition, the mean position and direction errors of registered sites were 2.2 mm and 11.8∘, respectively. In addition, sensitivity studies show the method's robustness to parameter variations. Lastly, we demonstrate the method's use in an image-guided system designed for guiding both phases of EBUS bronchoscopy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article