Your browser doesn't support javascript.
loading
Iatrogenic cardiac perforation due to pacemaker and defibrillator leads: a contemporary multicentre experience.
Waddingham, Peter H; Elliott, James; Bates, Alexander; Bilham, James; Muthumala, Amal; Honarbakhsh, Shohreh; Ullah, Waqas; Hunter, Ross J; Lambiase, Pier D; Lane, Rebecca E; Chow, Anthony W C.
Afiliação
  • Waddingham PH; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Elliott J; William Harvey Research Institute, Barts & The London School of Medicine & Dentistry, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK.
  • Bates A; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Bilham J; Department of Cardiology, University Hospital Southampton NHS Foundation Trust, Southampton, UK.
  • Muthumala A; Harefield Hospital, Royal Brompton, and Harefield NHS Trust, London, UK.
  • Honarbakhsh S; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Ullah W; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Hunter RJ; William Harvey Research Institute, Barts & The London School of Medicine & Dentistry, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK.
  • Lambiase PD; Department of Cardiology, University Hospital Southampton NHS Foundation Trust, Southampton, UK.
  • Lane RE; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
  • Chow AWC; William Harvey Research Institute, Barts & The London School of Medicine & Dentistry, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK.
Europace ; 24(11): 1824-1833, 2022 11 22.
Article em En | MEDLINE | ID: mdl-35894862
ABSTRACT

AIMS:

To determine the incidence, clinical features, management, and outcomes of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) lead cardiac perforation. Cardiac perforations due to PM and ICD leads are rare but serious complications. Clinical features vary widely and may cause diagnostic delay. Management strategies are non-guideline based due to paucity of data. METHODS AND

RESULTS:

A multicentre retrospective series including 3 UK cardiac tertiary centres from 2016 to 2020. Patient, device, and lead characteristics were obtained including 6-month outcomes. Seventy cases of perforation were identified from 10 631 procedures; perforation rate was 0.50% for local implants. Thirty-nine (56%) patients were female, mean ( ± standard deviation) age 74 ( ± 13.8) years. Left ventricular ejection fraction 51 ( ± 13.2) %. Median time to diagnosis was 9 (range 0-989) days. Computed tomography (CT) diagnosed perforation with 97% sensitivity. Lead parameter abnormalities were present in 86% (whole cohort) and 98.6% for perforations diagnosed >24 h. Chest pain was the commonest symptom, present in 46%. The management strategy was percutaneous in 98.6% with complete procedural success in 98.6%. Pericardial effusion with tamponade was present in 17% and was associated with significantly increased mortality and major complications. Anticoagulation status was associated with tamponade by multivariate analysis (odds ratio 21.7, 95% confidence interval 1.7-275.5, P = 0.018).

CONCLUSIONS:

Perforation was rare (0.50%) and managed successfully by a percutaneous strategy with good outcomes. Tamponade was associated with increased mortality and major complications. Anticoagulation status was an independent predictor of tamponade. Case complexity is highly variable and requires skilled operators with a multi-disciplinary approach to achieve good outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Traumatismos Cardíacos Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Desfibriladores Implantáveis / Traumatismos Cardíacos Tipo de estudo: Diagnostic_studies / Etiology_studies / Guideline / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article