Your browser doesn't support javascript.
loading
Direct detection of the crystal form of an active pharmaceutical ingredient in tablets by X-ray absorption fine structure spectroscopy.
Huang, Zhenni; Suzuki, Hironori; Ito, Masataka; Noguchi, Shuji.
Afiliação
  • Huang Z; Graduate School of Pharmaceutical Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba 274-8514, Japan.
  • Suzuki H; Graduate School of Pharmaceutical Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba 274-8514, Japan. Electronic address: hironori.suzuki@phar.toho-u.ac.jp.
  • Ito M; Graduate School of Pharmaceutical Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba 274-8514, Japan.
  • Noguchi S; Graduate School of Pharmaceutical Science, Toho University, 2-2-1 Miyama, Funabashi, Chiba 274-8514, Japan.
Int J Pharm ; 625: 122057, 2022 Sep 25.
Article em En | MEDLINE | ID: mdl-35908632
ABSTRACT
Different crystal forms of active pharmaceutical ingredients (APIs) may display variations in physicochemical properties. During the drug development process, the definitive purpose is to maintain homogeneous quality in a single crystalline form. Hence, it is important to evaluate and understand the properties of each crystal form of APIs in pharmaceutics. In this study, forms 0, Ⅰ, Ⅱ, III of bromhexine hydrochloride, and form S of bromhexine were characterized by the commonly used methods X-ray powder diffraction, thermogravimetry-differential thermal analysis, and single crystal structure X-ray diffraction. Additionally, X-ray absorption fine structure spectroscopy (XAFS), a seldom used method in the pharmaceutics discipline was also applied to explore the chemical environment of bromine atoms in forms 0, Ⅰ, Ⅱ and S as well as chloride ions in forms 0 to Ⅱ. The XAFS spectra of each form were different from each of the other forms which indicated the chemical environment around target elements in the crystal polymorphs were distinct. Then, we measured the commercial bromhexine hydrochloride tablets with XAFS measurement and found that XAFS could distinguish the crystal form in the tablets. Hence, we demonstrated that XAFS measurements would be applicable as one of the methods for the direct detection of APIs in the tablets.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bromoexina Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bromoexina Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article