Your browser doesn't support javascript.
loading
Simultaneous Quantification of Steroid Hormones Using hrLC-MS in Endocrine Tissues of Male Rats and Human Samples.
Bordanaba-Florit, Guillermo; Liempd, Sebastiaan van; Cabrera, Diana; Royo, Félix; Falcón-Pérez, Juan Manuel.
Afiliação
  • Bordanaba-Florit G; Exosomes Laboratory, Center for Cooperative Research in Biosciences (CIC bioGUNE), Basque Research and Technology Alliance (BRTA), 48160 Derio, Spain.
  • Liempd SV; Metabolomics Platform, Center for Cooperative Research in Biosciences (CIC bioGUNE), Basque Research and Technology Alliance (BRTA), 48160 Derio, Spain.
  • Cabrera D; Metabolomics Platform, Center for Cooperative Research in Biosciences (CIC bioGUNE), Basque Research and Technology Alliance (BRTA), 48160 Derio, Spain.
  • Royo F; Exosomes Laboratory, Center for Cooperative Research in Biosciences (CIC bioGUNE), Basque Research and Technology Alliance (BRTA), 48160 Derio, Spain.
  • Falcón-Pérez JM; Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (Ciberehd), 28029 Madrid, Spain.
Metabolites ; 12(8)2022 Jul 30.
Article em En | MEDLINE | ID: mdl-36005586
Steroid hormones play a vital role in the regulation of cellular processes, and dysregulation of these metabolites can provoke or aggravate pathological issues, such as autoimmune diseases and cancer. Regulation of steroid hormones involves different organs and biological compartments. Therefore, it is important to accurately determine their levels in tissues and biofluids to monitor changes after challenge or during disease. In this work, we have developed and optimized the extraction and quantification of 11 key members of the different steroid classes, including androgens, estrogens, progestogens and corticoids. The assay consists of a liquid/liquid extraction step and subsequent quantification by high-resolution liquid chromatography coupled time-of-flight mass spectrometry. The recoveries range between 74.2 to 126.9% and 54.9 to 110.7%, using a cell culture or urine as matrix, respectively. In general, the signal intensity loss due to matrix effect is no more than 30%. The method has been tested in relevant steroidogenic tissues in rat models and it has also been tested in human urine samples. Overall, this assay measures 11 analytes simultaneously in 6 min runtime and it has been applied in adrenal gland, testis, prostate, brain and serum from rats, and urine and extracellular vesicles from humans.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article