Your browser doesn't support javascript.
loading
Investigation into Biosorption of Pharmaceuticals from Aqueous Solutions by Biocomposite Material Based on Microbial Biomass and Natural Polymer: Process Variables Optimization and Kinetic Studies.
Rusu, Lacramioara; Grigoraș, Cristina-Gabriela; Simion, Andrei-Ionuț; Suceveanu, Elena-Mirela; Schnakovszky, Carol; Favier, Lidia.
Afiliação
  • Rusu L; Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 157 Calea Marasesti, 600115 Bacau, Romania.
  • Grigoraș CG; Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 157 Calea Marasesti, 600115 Bacau, Romania.
  • Simion AI; Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 157 Calea Marasesti, 600115 Bacau, Romania.
  • Suceveanu EM; Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 157 Calea Marasesti, 600115 Bacau, Romania.
  • Schnakovszky C; Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 157 Calea Marasesti, 600115 Bacau, Romania.
  • Favier L; Ecole Nationale Supérieure de Chimie de Rennes, University of Rennes, CNRS, UMR 6226, CEDEX 7, 35708 Rennes, France.
Polymers (Basel) ; 14(16)2022 Aug 19.
Article em En | MEDLINE | ID: mdl-36015645
ABSTRACT
Biosorbtive removal of the antibacterial drug, ethacridine lactate (EL), from aqueous solutions was investigated using as biosorbent Saccharomyces pastorianus residual biomass immobilized in calcium alginate. The aim of this work was to optimize the biosorption process and to evaluate the biosorption capacity in the batch system. Response surface methodology, based on a Box-Behnken design, was used to optimize the EL biosorption parameters. Two response functions (removal efficiency and biosorption capacity) were maximized dependent on three factors initial concentration of EL solution, contact time, and agitation speed. The highest values for the studied functions (89.49%, 26.04 mg/g) were obtained in the following operational conditions EL initial concentration 59.73 mg/L; contact time 94.26 min; agitation speed 297.57 rpm. A number of nonlinear kinetic models, including pseudo-first-order, pseudo-second-order, Elovich, and Avrami, were utilized to validate the biosorption kinetic behavior of EL in the optimized conditions. The kinetic data fitted the pseudo-first-order and Avrami models. The experimental results demonstrated that the optimized parameters (especially the agitation speed) significantly affect biosorption and should be considered important in such studies.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article