Your browser doesn't support javascript.
loading
An Evaluation of a New Quantitative Point-of Care Diagnostic to Measure Glucose-6-phosphate Dehydrogenase Activity.
Bahk, Young Yil; Ahn, Seong Kyu; Jeon, Heung Jin; Na, Byoung-Kuk; Lee, Sung-Keun; Shin, Ho-Joon.
Afiliação
  • Bahk YY; Department of Biotechnology, College of Biomedical and Health Science, Konkuk University, Chungju 27478, Korea.
  • Ahn SK; Infectious Diseases Investigation Division, Jeonnam Institute of Public Health and Environment, Muan 58568, Korea.
  • Jeon HJ; Infection Control Convergence Research Center, Chungnam National University College of Medicine, Deajeon 35015, Korea.
  • Na BK; Department of Parasitology and Tropical Medicine, Institute of Health Sciences, College of Medicine, Gyeongsang National University, Jinju 52727, Korea.
  • Lee SK; Department of Pharmacology, Inha University School of Medicine, Incheon 22212, Korea.
  • Shin HJ; Department of Microbiology, Ajou University School of Medicine, Suwon 16499, Korea.
Korean J Parasitol ; 60(4): 281-288, 2022 Aug.
Article em En | MEDLINE | ID: mdl-36041490
ABSTRACT
Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI) 89.3-100%) and a specificity of 100% (95% CI 94.3-100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malária Vivax / Deficiência de Glucosefosfato Desidrogenase / Malária / Antimaláricos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malária Vivax / Deficiência de Glucosefosfato Desidrogenase / Malária / Antimaláricos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article