AIMS:
Multiple re-entry circuits may operate simultaneously in the atria in the form of dual loop re-entry using a common isthmus, or multiple re-entrant loops without a common isthmus. When two or more re-entrant circuits coexist, ablation of an individual isthmus may lead to a seamless transition (without significant changes in surface electrocardiogram, coronary sinus activation or tachycardia cycle length) to a second rhythm, and the isthmus block can go unnoticed. METHODS ANDRESULTS:
We hypothesize and subsequently illustrate in three patient cases, methods to rapidly identify a transition in the rhythm and isthmus block using local electrogram changes at the ablation site.CONCLUSION:
Local activation sequence changes, electrogram timing, and the behaviour of pre-existing double potentials can reveal isthmus block promptly when rhythm transitions occur during ablation of multiloop re-entry tachycardias.Palavras-chave