Your browser doesn't support javascript.
loading
A homogeneous enzyme-free ratiometric immunoassay for the determination of C-peptide.
Sun, Wenjing; Xia, Huan; Zhang, Nan; Nan, Jie; Yu, Guanggui; Zhao, Hongwei; Sai, Na.
Afiliação
  • Sun W; Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070, Tianjin, China; Department of Nutrition, Tianjin Huanhu Hospital, 300350, Tianjin, China.
  • Xia H; Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070, Tianjin, China.
  • Zhang N; Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070, Tianjin, China.
  • Nan J; Inspection Department, Tianjin Xiqing Hospital, 300380, Tianjin, China.
  • Yu G; Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070, Tianjin, China.
  • Zhao H; Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070, Tianjin, China.
  • Sai N; Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, 300070, Tianjin, China. Electronic address: saina@tmu.edu.cn.
Anal Biochem ; 658: 114899, 2022 12 01.
Article em En | MEDLINE | ID: mdl-36126761
In this study, a homogeneous enzyme-free ratiometric (HOMO- EF-RA) immunoassay was developed for the sensitive detection of C-peptide. In the immunoassay, there have been a miscible detection system by mixing with the fluorescent quantum dots conjugated antigen (QD-Ag conjugates) and the dylight dye conjugated antibody (DL-Ab conjugates). When connecting between Ag-QD conjugate and Ab-DL conjugate by specific recognition, the system emitted fluorescence resonant energy transfer (FRET). The target C-peptide can inhibit the connection and FRET formation between QD-Ag conjugates and DL-Ab conjugates, thus changing the dual fluorescence. By measuring the ratio dual fluorescence changes of the system, the content of C-peptide was evaluated without any enzyme used and multiple incubation and washing steps. This immunoassay realized the highly sensitive (as low as 0.12 ng mL-1), selective and rapid (as less as 6 min) detection of C-peptide. Furthermore, the simple and convenient immunoassay was applied successfully to the determination of C-peptide in real serum samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pontos Quânticos Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pontos Quânticos Idioma: En Ano de publicação: 2022 Tipo de documento: Article