Your browser doesn't support javascript.
loading
Meta-analysis of short- and long-term clinical outcomes of the self-expanding Evolut R/pro valve versus the balloon-expandable Sapien 3 valve for transcatheter aortic valve implantation.
Lerman, Tsahi T; Levi, Amos; Kornowski, Ran.
Afiliação
  • Lerman TT; Department of Internal Medicine F-Recanati, Beilinson Hospital, Rabin Medical Center, Petah Tikva, Israel; Department of Cardiology, Rabin Medical Center, Petah Tikva, Israel; The Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel. Electronic address: tsahilerman@gmail.com.
  • Levi A; Department of Cardiology, Rabin Medical Center, Petah Tikva, Israel; The Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Kornowski R; Department of Cardiology, Rabin Medical Center, Petah Tikva, Israel; The Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Int J Cardiol ; 371: 100-108, 2023 Jan 15.
Article em En | MEDLINE | ID: mdl-36130623
BACKGROUND: The Evolut R/Pro and the Sapien 3 are the most commonly valve systems used today for transcatheter aortic valve implantation (TAVI). However, there is a still uncertainty regarding the efficacy and safety comparison of these two valves. METHODS: We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) and observational studies comparing the Evolut R/Pro versus the Sapien 3. The primary outcome was all-cause mortality (short and long-term). The secondary outcomes were stroke, bleeding, permanent pacemaker implantation (PPI), acute kidney injury (AKI), major vascular complication, device success, moderate- severe aortic regurgitation (AR), and pressure gradients. RESULTS: Twenty-one publications totaling 35,248 patients were included in the analysis. Evolut R/Pro was associated with higher risk of short-term all-cause mortality (OR = 1.31;95% CI 1.15-1.49, p < 0.001) and a trend of higher long-term mortality (OR = 1.07;95% CI 1.00-1.16, p = 0.06). The Evolut R/Pro was associated with higher risk of PPI and AR and lower risk for bleeding, major vascular complication, and pressure gradients. There was no significant difference between the groups regarding the risk of stroke, AKI and device success. CONCLUSIONS: The Evolut R/Pro valve system compared to the Sapien 3 is associated with higher risk of short-term mortality, significant AR and PPI while providing the advantage of lower risk of bleeding, major vascular complication, and lower residual transvalvular gradients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Acidente Vascular Cerebral / Injúria Renal Aguda / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Observational_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Acidente Vascular Cerebral / Injúria Renal Aguda / Substituição da Valva Aórtica Transcateter Tipo de estudo: Clinical_trials / Observational_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article