Your browser doesn't support javascript.
loading
Colorimetric Biosensors Based on Polymer/Gold Hybrid Nanoparticles: Topological Effects of the Polymer Coating.
Wang, Ruosong; Schirmer, Lucas; Wieduwilt, Torsten; Förster, Ronny; Schmidt, Markus A; Freudenberg, Uwe; Werner, Carsten; Fery, Andreas; Rossner, Christian.
Afiliação
  • Wang R; Institut für Physikalische Chemie und Physik der Polymere, Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Straße 6, D-01069 Dresden, Germany.
  • Schirmer L; Max Bergmann Center of Biomaterials Dresden (MBC), Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Straße 6, D-01069 Dresden, Germany.
  • Wieduwilt T; Leibniz-Institut für Photonische Technologien, Albert-Einstein-Straße 9, D-07745 Jena, Germany.
  • Förster R; Leibniz-Institut für Photonische Technologien, Albert-Einstein-Straße 9, D-07745 Jena, Germany.
  • Schmidt MA; Leibniz-Institut für Photonische Technologien, Albert-Einstein-Straße 9, D-07745 Jena, Germany.
  • Freudenberg U; Abbe Center of Photonics and Faculty of Physics, FSU Jena, 07745 Jena, Germany.
  • Werner C; Otto Schott Institute of Material Research, FSU Jena, 07745 Jena, Germany.
  • Fery A; Max Bergmann Center of Biomaterials Dresden (MBC), Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Straße 6, D-01069 Dresden, Germany.
  • Rossner C; Max Bergmann Center of Biomaterials Dresden (MBC), Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Straße 6, D-01069 Dresden, Germany.
Langmuir ; 38(40): 12325-12332, 2022 10 11.
Article em En | MEDLINE | ID: mdl-36154138
Gold nanoparticles decorated with analyte recognition units can form the basis of colorimetric (bio)sensors. The presentation of those recognition units may play a critical role in determining sensor sensitivity. Herein, we use a model system to investigate the effect of the architecture of a polymeric linker that connects gold nanoparticles with the recognition units. Our results show that the number of the latter that can be adsorbed during the assembly of the colorimetric sensors depends on the linker topology. We also show that this may lead to substantial differences in colorimetric sensor performance, particularly in situations in which the interactions with the analyte are comparably weak. Finally, we discuss design principles for efficient colorimetric sensor materials based on our findings.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article