Your browser doesn't support javascript.
loading
HiHi fMRI: a data-reordering method for measuring the hemodynamic response of the brain with high temporal resolution and high SNR.
Nagy, Zoltan; Hutton, Chloe; David, Gergely; Hinterholzer, Natalie; Deichmann, Ralf; Weiskopf, Nikolaus; Vannesjo, S Johanna.
Afiliação
  • Nagy Z; Laboratory for Social and Neural Systems Research (SNS Lab), University Hospital Zurich, Rämistrasse 100, University of Zurich, Zurich CH-8091, Switzerland.
  • Hutton C; Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, 12 Queen Square, University College London, London WC1N 3BG, UK.
  • David G; Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, 12 Queen Square, University College London, London WC1N 3BG, UK.
  • Hinterholzer N; Spinal Cord Injury Center, Balgrist University Hospital, Forchstrasse 340, University of Zurich, Zurich CH-8008, Switzerland.
  • Deichmann R; SCMI, Swiss Center for Musculoskeletal Imaging, Balgrist Campus AG, Lengghalde 5, Zurich CH-8008, Switzerland.
  • Weiskopf N; Wellcome Centre for Human Neuroimaging, UCL Queen Square Institute of Neurology, 12 Queen Square, University College London, London WC1N 3BG, UK.
  • Vannesjo SJ; Brain Imaging Centre, Goethe University Frankfurt, University Hospital Campus, Haus 95H, Schleusenweg 2-16, Frankfurt am Main D-60528, Germany.
Cereb Cortex ; 33(8): 4606-4611, 2023 04 04.
Article em En | MEDLINE | ID: mdl-36169574
ABSTRACT
There is emerging evidence that sampling the blood-oxygen-level-dependent (BOLD) response with high temporal resolution opens up new avenues to study the in vivo functioning of the human brain with functional magnetic resonance imaging. Because the speed of sampling and the signal level are intrinsically connected in magnetic resonance imaging via the T1 relaxation time, optimization efforts usually must make a trade-off to increase the temporal sampling rate at the cost of the signal level. We present a method, which combines a sparse event-related stimulus paradigm with subsequent data reshuffling to achieve high temporal resolution while maintaining high signal levels (HiHi). The proof-of-principle is presented by separately measuring the single-voxel time course of the BOLD response in both the primary visual and primary motor cortices with 100-ms temporal resolution.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article