Your browser doesn't support javascript.
loading
The predictability of expansion with Invisalign: A retrospective cohort study.
Tien, Richard; Patel, Vraj; Chen, Tulrica; Lavrin, Igor; Naoum, Steven; Lee, Richard J H; Goonewardene, Mithran S.
Afiliação
  • Tien R; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia.
  • Patel V; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia.
  • Chen T; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia.
  • Lavrin I; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia; Private practice, Melbourne, Victoria, Australia.
  • Naoum S; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia.
  • Lee RJH; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia.
  • Goonewardene MS; University of Western Australia Dental School, the University of Western Australia, Nedlands, Western Australia, Australia. Electronic address: mithran.goonewardene@uwa.edu.au.
Am J Orthod Dentofacial Orthop ; 163(1): 47-53, 2023 Jan.
Article em En | MEDLINE | ID: mdl-36195544
ABSTRACT

INTRODUCTION:

Few studies have evaluated the predictability of expansion with Invisalign for the current SmartTrack material.

METHODS:

Pretreatment, predicted, and posttreatment digital models from Invisalign's ClinCheck software were obtained for 57 adult patients with a planned arch expansion of at least 3 mm. Arch width measurements were collected using a software measuring tool (MeshLab), Invisalign's arch width table, and the centroid of the clinical crown. Data for 30 patients were remeasured for each method to assess intrarater reliability. Predictability of expansion was calculated by comparing the amount of achieved expansion to predicted expansion.

RESULTS:

The predictability of expansion across centroids for the maxillary teeth was 72.2% canines, 78.9% first premolars, 81.1% second premolars, 63.5% first molars, and 41.5% second molars. The predictability of expansion across centroids for the mandibular teeth was 82.3% canines, 93.0% first premolars, 87.7% second premolars, 79.8% first molars, and 42.9% second molars. The average expansion was significantly different from that predicted for each type of tooth in both the maxilla and mandible. Both underexpansion and overexpansion were observed. Arch width measurement reliability for each employed method was as follows MeshLab (average error 0.197 mm); calculated centroids (0.002 mm); ClinCheck arch width table (0.000 mm).

CONCLUSIONS:

On average, the amount of predicted expansion is not achieved with the Invisalign system and varies according to tooth type and arch. Discretion is required when overcorrecting to compensate for expansion inaccuracy. Both underexpansion and overexpansion were observed; further investigation into factors influencing underexpansion and overexpansion is required.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aparelhos Ortodônticos Removíveis Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aparelhos Ortodônticos Removíveis Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article