Your browser doesn't support javascript.
loading
DNA-Immobilized Special Conformation Recognition of L-Penicillamine Using a Chiral Molecular Imprinting Technique.
Zhang, Lianming; Luo, Kui; Gao, Jingxia; Li, Jianping.
Afiliação
  • Zhang L; College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
  • Luo K; College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
  • Gao J; College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
  • Li J; College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004, China.
Polymers (Basel) ; 14(19)2022 Oct 02.
Article em En | MEDLINE | ID: mdl-36236082
A new chiral molecularly imprinted polymer (MIP) sensor with dual recognition ability was developed for the highly selective separation of enantiomers with toxic side effects in drugs. The sensor contains double-stranded deoxyribonucleic acid (dsDNA) as the element that immobilizes the chiral molecular conformation: the dsDNA enables the imprinted cavities to match the three-dimensional structure and functional groups from the chiral molecule. By embedding the spatial orientation of dsDNA in MIPs, one can accurately capture and immobilize the molecular conformation, eliminating the influence of interfering analogues. Herein, L-penicillamine (L-Pen) was selected as the chiral template molecule and embedded into dsDNA to form dsDNA-L-Pen complex, which was then embedded into the MIPs by electropolymerization. After elution, the stereo-selective imprinted cavities were obtained. The ATATATATATAT-TATATATATATA base sequence showed a high affinity for the embedded L-Pen, which endowed the imprinted cavities with a larger number of sites and improved the selectivity toward Pen enantiomers. Under the optimal working conditions, the current response of the MIP/dsDNA sensor exhibited a positive linear relationship with the logarithm of the L-Pen concentration in the range of 3.0 × 10-16 to 3.0 × 10-13 mol/L, and the detection limit was 2.48 × 10-16 mol/L. After the introduction of dsDNA into the MIP, the selectivity of the sensor toward D-Pen increased by 6.4 times, and the sensor was successfully applied in the analysis of L-Pen in penicillamine tablets.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article