[Study on Parametric Release of Ethylene Oxide Sterilization of Medical Devices].
Huang, Hongxin; Hu, Changming; Liu, Wenyi; Cui, Wenbo; Xu, Haiying; Zhu, Peiping.
Afiliação
  • Huang H; Guangdong Medical Devices Quality Surveillance and Test Institute, Guangzhou, 510663.
  • Hu C; Guangdong Medical Devices Quality Surveillance and Test Institute, Guangzhou, 510663.
  • Liu W; Suzhou GOLAS Medical Technology Co. Ltd., Suzhou, 215000.
  • Cui W; Xinxiang Huaxi Sanitary Materials Co. Ltd., Xinxiang, 453412.
  • Xu H; Suzhou Prosteri Medical Technology Co. Ltd., Suzhou, 215000.
  • Zhu P; Suzhou GOLAS Medical Technology Co. Ltd., Suzhou, 215000.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(5): 574-577, 2022 Sep 30.
Article em Zh | MEDLINE | ID: mdl-36254490
ABSTRACT
This study briefly introduces the basic theory of sterilization, the characteristics of ethylene oxide sterilization for medical devices and the key factors about sterilization effectiveness, analyzes and compares three methods used in the product release of medical devices sterilized by ethylene oxide test for sterility, traditional release and parametric release, and focuses on the theoretical basis, feasibility, validation requirements, advantages and disadvantages of parametric release.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esterilização / Óxido de Etileno Idioma: Zh Ano de publicação: 2022 Tipo de documento: Article