Your browser doesn't support javascript.
loading
Human cardiomyocytes are more susceptible to irreversible electroporation by pulsed electric field than human esophageal cells.
Casciola, Maura; Keck, Devin; Feaster, Tromondae K; Blinova, Ksenia.
Afiliação
  • Casciola M; Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA.
  • Keck D; Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA.
  • Feaster TK; Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA.
  • Blinova K; Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, USA.
Physiol Rep ; 10(20): e15493, 2022 10.
Article em En | MEDLINE | ID: mdl-36301726

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroporação / Miócitos Cardíacos Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroporação / Miócitos Cardíacos Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article