Your browser doesn't support javascript.
loading
Prediction of Preterm Birth with Serial Measurements of Ultrasound Markers.
Camen, Ioana Victoria; Manolea, Maria Magdalena; Vrabie, Sidonia Catalina; Sandulescu, Maria Sidonia; Serbanescu, Mircea Sebastian; Boldeanu, Mihail Virgil; Novac, Liliana; Istrate-Ofiteru, Anca Maria; Neamtu, Simona Daniela; Dijmarescu, Anda Lorena.
Afiliação
  • Camen IV; Ph.D. student, Doctoral School, University of Medicine and Pharmacology of Craiova, Romania.
  • Manolea MM; Department of Obstetrics and Gynecology, "Filantropia" Hospital from Craiova.
  • Vrabie SC; Obstetrics and Gynecology Department, University of Medicine and Pharmacology of Craiova, Romania.
  • Sandulescu MS; Department of Obstetrics and Gynecology, "Filantropia" Hospital from Craiova.
  • Serbanescu MS; Obstetrics and Gynecology Department, University of Medicine and Pharmacology of Craiova, Romania.
  • Boldeanu MV; Department of Obstetrics and Gynecology, "Filantropia" Hospital from Craiova.
  • Novac L; Obstetrics and Gynecology Department, University of Medicine and Pharmacology of Craiova, Romania.
  • Istrate-Ofiteru AM; Department of Obstetrics and Gynecology, "Filantropia" Hospital from Craiova.
  • Neamtu SD; Medical Informatics Department, University of Medicine and Pharmacology of Craiova, Romania.
  • Dijmarescu AL; Immunology Department, University of Medicine and Pharmacy of Craiova, Romania.
Curr Health Sci J ; 48(2): 162-168, 2022.
Article em En | MEDLINE | ID: mdl-36320871
ABSTRACT
To compare the ability of cervical length (CL), anterior cervical angle (ACA), and cervical consistency index (CCI) to predict premature birth.

METHODS:

This prospective study involved 85 pregnant women who gave birth prematurely and a control group of 31 pregnant women who gave birth at term. The study was performed in the Obstetrics and Gynecology Clinic of the Municipal Clinical Hospital Filanthropia Craiova between January 1, 2019, and January 1, 2022. Cases were examined using transvaginal ultrasonography (TVU) in the second and third trimesters of pregnancy, and cervical length (CL), Anterior Cervical Angle (ACA), and Cervical Consistency Index (CCI) were measured.

RESULTS:

The mean value from the three measurements at all three parameters was statistically significant with preterm birth (p<0.05). Cervical length <25mm, was highly significant in the prediction of preterm labor with a sensitivity of 99%, specificity of 61%, positive predictive value (PPV) of 78%, negative predictive value (NPV) of 97 %, and a positive likelihood ratio (LR+) of 2.54 and negative likelihood ratio (LR-) of 0.02. CCI also remains, despite low specificity and PPV values, a potential predictive parameter in the prediction of preterm birth, with a sensitivity of 73%, NPV of 92% and a LR+of 1.32 and LR- of 0.6 also correlated with CL, CCI being more difficult to interpret as an independent predictive parameter.

CONCLUSIONS:

CL remains the standard parameter for predicting the preterm birth, but in combination with other parameters, the prediction rate can increase significantly.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article