Your browser doesn't support javascript.
loading
Comparative effectiveness of devices for transcatheter closure of atrial septal defects: Systematic review and network meta-analysis.
Vishwanath, Varnita; Akseer, Selai; Frankfurter, Claudia; Reza, Seleman; Farrell, Ashley; Horlick, Eric; Abrahamyan, Lusine.
Afiliação
  • Vishwanath V; Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre (PMCC), University Health Network, ON M5G 2N2 Toronto, Canada.
  • Akseer S; Toronto General Hospital Research Institute, University Health Network, 10th Floor Eaton North, Room 237, 200, Elizabeth Street, ON M5G 2C4 Toronto, Canada; Institute of Health Policy, Management and Evaluation (IHPME), University of Toronto, Toronto ON M5T 3M6, Canada.
  • Frankfurter C; Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre (PMCC), University Health Network, ON M5G 2N2 Toronto, Canada.
  • Reza S; Institute of Health Policy, Management and Evaluation (IHPME), University of Toronto, Toronto ON M5T 3M6, Canada.
  • Farrell A; Library & Information Services, University Health Network, Toronto ON M5G 2C4, Canada.
  • Horlick E; Toronto Congenital Cardiac Centre for Adults, Peter Munk Cardiac Centre (PMCC), University Health Network, ON M5G 2N2 Toronto, Canada.
  • Abrahamyan L; Toronto General Hospital Research Institute, University Health Network, 10th Floor Eaton North, Room 237, 200, Elizabeth Street, ON M5G 2C4 Toronto, Canada; Institute of Health Policy, Management and Evaluation (IHPME), University of Toronto, Toronto ON M5T 3M6, Canada. Electronic address: lusine.ab
Arch Cardiovasc Dis ; 115(12): 664-674, 2022 Dec.
Article em En | MEDLINE | ID: mdl-36336619
Atrial septal defect is a common congenital heart disease, producing a left-to-right shunt in the atrial septum; the current preferred treatment is transcatheter device closure. The aim is to conduct a systematic review to synthesize information on the comparative effectiveness and safety of atrial septal defect closure devices. The methods used: a comprehensive search of Ovid MEDLINE®, Embase, and Cochrane Central databases was conducted. Studies comparing procedural and follow-up outcomes of atrial septal defect devices were included. Network meta-analyses were conducted to generate direct and indirect evidence for comparative effectiveness and safety outcomes between devices. The results are as follows: Twelve studies met our inclusion criteria and were compared in network meta-analyses. The meta-analyses evaluated contemporary devices: the AMPLATZER Septal Occluder; the GORE CARDIOFORM Septal Occluder; the Figulla Flexible II Occluder; the CeraFlex Septal Occluder; and the HELEX Septal Occluder. These studies represented 3998 patients. The primary safety and efficacy outcomes were device embolization and follow-up residual shunt, respectively. Secondary clinical outcomes included procedural success and major and minor complications. No differences were found between devices in terms of device embolization and secondary clinical outcomes. Follow-up residual shunt was higher with the HELEX Septal Occluder compared with the AMPLATZER Septal Occluder (odds ratio 2.92, 95% confidence interval 1.12-7.61). To conclude: although most outcomes were similar between devices, evidence was largely based on observational low-quality studies. There were inconsistencies in outcome reporting and definitions; this merits future studies, with head-to-head device comparisons and standardization of outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivo para Oclusão Septal / Comunicação Interatrial Tipo de estudo: Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivo para Oclusão Septal / Comunicação Interatrial Tipo de estudo: Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article