Your browser doesn't support javascript.
loading
X-ray diffraction with micrometre spatial resolution for highly absorbing samples.
Chakrabarti, Prerana; Wildeis, Anna; Hartmann, Markus; Brandt, Robert; Döhrmann, Ralph; Fevola, Giovanni; Ossig, Christina; Stuckelberger, Michael Elias; Garrevoet, Jan; Falch, Ken Vidar; Galbierz, Vanessa; Falkenberg, Gerald; Modregger, Peter.
Afiliação
  • Chakrabarti P; Physics Department, University of Siegen, 57072 Siegen, Germany.
  • Wildeis A; Mechanical Engineering Department, University of Siegen, 57076 Siegen, Germany.
  • Hartmann M; Mechanical Engineering Department, University of Siegen, 57076 Siegen, Germany.
  • Brandt R; Mechanical Engineering Department, University of Siegen, 57076 Siegen, Germany.
  • Döhrmann R; Center for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Fevola G; Center for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Ossig C; Center for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Stuckelberger ME; Center for X-ray and Nano Science CXNS, Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Garrevoet J; Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Falch KV; Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Galbierz V; Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Falkenberg G; Deutsches Elektronen-Synchrotron DESY, 22607 Hamburg, Germany.
  • Modregger P; Physics Department, University of Siegen, 57072 Siegen, Germany.
J Synchrotron Radiat ; 29(Pt 6): 1407-1413, 2022 Nov 01.
Article em En | MEDLINE | ID: mdl-36345748
ABSTRACT
X-ray diffraction with high spatial resolution is commonly used to characterize (poly)crystalline samples with, for example, respect to local strain, residual stress, grain boundaries and texture. However, the investigation of highly absorbing samples or the simultaneous assessment of high-Z materials by X-ray fluorescence have been limited due to the utilization of low photon energies. Here, a goniometer-based setup implemented at the P06 beamline of PETRA III that allows for micrometre spatial resolution with a photon energy of 35 keV and above is reported. A highly focused beam was achieved by using compound refractive lenses, and high-precision sample manipulation was enabled by a goniometer that allows up to 5D scans (three rotations and two translations). As experimental examples, the determination of local strain variations in martensitic steel samples with micrometre spatial resolution, as well as the simultaneous elemental distribution for high-Z materials in a thin-film solar cell, are demonstrated. The proposed approach allows users from the materials-science community to determine micro-structural properties even in highly absorbing samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article