Your browser doesn't support javascript.
loading
Vasopressors improve outcomes in autologous free tissue transfer: A systematic review and meta-analysis.
Noori, Omar; Pereira, Jose L; Stamou, Despoina; Ch'ng, Sydney; Varey, Alexander Hr.
Afiliação
  • Noori O; School of Medicine, Faculty of Health and Medicine, University of Sydney, Sydney, NSW, Australia.
  • Pereira JL; School of Medicine, Faculty of Health and Medicine, University of Sydney, Sydney, NSW, Australia.
  • Stamou D; Department of Anaesthesia, Westmead Hospital, Sydney, NSW, Australia.
  • Ch'ng S; School of Medicine, Faculty of Health and Medicine, University of Sydney, Sydney, NSW, Australia; Melanoma Institute Australia, North Sydney, NSW, Australia; Department of Plastic Surgery, Royal Prince Alfred Hospital, Sydney, NSW, Australia; Royal Prince Alfred Hospital Institute of Academic Surger
  • Varey AH; School of Medicine, Faculty of Health and Medicine, University of Sydney, Sydney, NSW, Australia; Melanoma Institute Australia, North Sydney, NSW, Australia; Department of Plastic Surgery, Westmead Hospital, Sydney, NSW, Australia. Electronic address: alexander.varey@sydney.edu.au.
J Plast Reconstr Aesthet Surg ; 81: 151-163, 2023 06.
Article em En | MEDLINE | ID: mdl-36379854
ABSTRACT

BACKGROUND:

Vasopressor use in patients undergoing autologous free tissue transfer is generally discouraged by surgeons perioperatively. This stems from concerns about the increased risk of flap failure with their use. The aim of this systematic review was to investigate the evidence and quantify any harm or benefits associated with vasopressor use.

METHODS:

A systematic review of the literature was undertaken using OVID Medline to search 13 databases. The search strategy used Boolean operators, text word searches, truncation symbols, and adjacency searching. Terms such as "free flap," "free tissue graft," and "free tissue transfer" were used along with a list of appropriate vasopressors. The primary outcome was free flap failure, on which a meta-analysis was performed.

RESULT:

The search initially identified 1029 unique articles, which after title and abstract screening was reduced to 112, of which 15 remained after full-text screening for inclusion in the review and analysis. We analyzed data from 8427 flaps, with 6695 having received a vasopressor. Meta-analysis demonstrated that vasopressor use reduced the relative risk (RR) of free flap failure (RR 0.70; 95% CI 0.50-0.97; p = 0.03) but did not affect rates of other adverse events (RR 0.81; 95% CI 0.63-1.05; p = 0.11).

CONCLUSION:

Vasopressor use appears beneficial for autologous free tissue transfer, with evidence that it reduced the risk of flap failure without impacting the rates of other adverse events. The use of vasopressors should, therefore, be encouraged on a case-by-case basis, depending upon the general physiological needs of the patient.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Cirurgia Plástica / Retalhos de Tecido Biológico Tipo de estudo: Etiology_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Cirurgia Plástica / Retalhos de Tecido Biológico Tipo de estudo: Etiology_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article