Your browser doesn't support javascript.
loading
[Value of functional echocardiographic parameters in predicting refractory septic shock in neonates]. / 功能性超声心动图参数在新生儿脓毒症休克中的临床应用价值.
Zhong, Jun-Juan; Mo, Jing; Shuai, Chun; Wang, Yue; Zhang, Jing; Ma, Dong-Ju; Lin, Ying-Yi; Ye, Xiu-Zhen.
Afiliação
  • Zhong JJ; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Mo J; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Shuai C; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Wang Y; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Zhang J; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Ma DJ; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Lin YY; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
  • Ye XZ; Department of Neonatology, Guangdong Women and Children's Hospital/Guangdong Neonatal ICU Medical Quality Control Center, Guangzhou 510000, China.
Zhongguo Dang Dai Er Ke Za Zhi ; 24(11): 1213-1218, 2022 Nov 15.
Article em Zh | MEDLINE | ID: mdl-36398546
ABSTRACT

OBJECTIVES:

To study the value of functional echocardiographic parameters in predicting refractory septic shock in neonates.

METHODS:

A total of 72 neonates with septic shock were enrolled. According to the highest value of septic shock score, they were divided into two groups refractory (n=30) and non-refractory (n=42). The two groups were compared in terms of clinical data, laboratory findings, and functional echocardiographic parameters. The receiver operating characteristic (ROC) curve was used to evaluate the performance of functional echocardiographic parameters in predicting refractory septic shock.

RESULTS:

Compared with the non-refractory group, the refractory group had significantly lower cardiac output and cardiac index (CI) and a significantly higher mean arterial pressure (MAP)/CI ratio (P<0.05). CI had a cut-off value of 2.6 L/(min·m2), a sensitivity of 79%, a specificity of 83%, and an area under the ROC curve (AUC) of 0.841 in predicting septic shock-related death (P<0.05), and MAP/CI ratio had a cut-off value of 11.4, a sensitivity of 83%, a specificity of 73%, and an AUC of 0.769 (P<0.05). CI had a cut-off value of 2.9 L/(min·m2), a sensitivity of 69%, a specificity of 69%, and an AUC of 0.717 in predicting all-cause death within 28 days (P<0.05).

CONCLUSIONS:

CI and MAP/CI ratio can be useful for early prediction of septic shock-related death in neonates.