Your browser doesn't support javascript.
loading
Does stem profile have an impact on the failure patterns in revision total knee arthroplasty?
Maslaris, Alexander; Tsiridis, Eleftherios; Schoeneberg, Carsten; Pass, Bastian; Spyrou, Georgios; Maris, Alexandros; Matziolis, Georg.
Afiliação
  • Maslaris A; Department of Orthopedics, Waldkliniken Eisenberg, Jena University Hospital, Klosterlausnitzer Str. 81, 07607, Eisenberg, Germany. alexander_maslaris@hotmail.com.
  • Tsiridis E; Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131, Essen, Germany. alexander_maslaris@hotmail.com.
  • Schoeneberg C; Academic Orthopedic Department, Papageorgiou General Hospital, Aristotle University Medical School, Thessaloniki, GRC, Greece.
  • Pass B; Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131, Essen, Germany.
  • Spyrou G; Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131, Essen, Germany.
  • Maris A; Department of Orthopedics and Trauma Surgery, Alfried-Krupp Hospital Essen, Alfried-Krupp-Straße 21, 45131, Essen, Germany.
  • Matziolis G; Department of Orthopedics, Great Ormond Street Hospital NHS Foundation Trust, Great Ormond Street, London, WC1N 3JH, UK.
Arch Orthop Trauma Surg ; 143(3): 1549-1569, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36450936
ABSTRACT

INTRODUCTION:

Revision total knee arthroplasty (RTKA) has been increasing continuously. The results of RTKA still remain unsatisfactory. Failure patterns and risk factors in RTKA were thoroughly analyzed, with periprosthetic joint infections (PJI) and aseptic loosening remaining at the forefront of re-revision (ReRTKA) causes. While there is evidence that stem profile impacts the revisability of cemented implants, its association with the modes of RTKA failure is unknown.

METHODS:

50 consecutive ReRTKA performed in a single orthopedic center during 2016-2017 were retrospectively analyzed. The cases were stratified according to age, sex, number of preexisting revisions, fixation technique, stem design and causes of re-revision. All explanted implants with conical vs. cylindrical stem profiles were compared.

RESULTS:

Mean age was 67 ± 11.5, and 54% were females. 72% of the cases had ≥ 3 previous revisions. 88% were full-cemented, 3% hybrid and 9% press-fit stems. 36% of the RTKA had conical, 58% cylindrical and 6% combined stem profiles. 92% of the RTKA components were removed. Removal causes were PJI (52.2%), aseptic loosening (34.8%), implant malposition (9.8%), painful knee (1.1%) and instability (2.2%). While the overall RTKA failure patterns were equally distributed between conical and cylindrical stems, subgroup analysis of only cemented ReRTKA revealed a higher incidence of aseptic loosening within cylindrical stem profiles (46.7% vs. 25.7%, P = 0.05).

CONCLUSION:

Stem profile may have an impact on the process of aseptic loosening in cemented non-metaphyseal engaging RTKA, with cylindrical designs tending to worse outcomes than conical designs. Large cohort studies could provide more clarity on current observation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Prótese do Joelho Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia do Joelho / Prótese do Joelho Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2023 Tipo de documento: Article