Your browser doesn't support javascript.
loading
Lanthanide Encoded Logically Gated Micromachine for Simultaneous Detection of Nucleic Acids and Proteins by Elemental Mass Spectrometry.
Yang, Peng; Zhou, Rongxing; Hu, Jing; Du, Lijie; Li, Feng; Chen, Junbo; Hou, Xiandeng.
Afiliação
  • Yang P; Biliary Surgical Department of West China Hospital, Sichuan University, Chengdu, Sichuan 610064, China.
  • Zhou R; Analytical & Testing Centre, Sichuan University, Chengdu, Sichuan 610064, China.
  • Hu J; Biliary Surgical Department of West China Hospital, Sichuan University, Chengdu, Sichuan 610064, China.
  • Du L; Analytical & Testing Centre, Sichuan University, Chengdu, Sichuan 610064, China.
  • Li F; Analytical & Testing Centre, Sichuan University, Chengdu, Sichuan 610064, China.
  • Chen J; Key Laboratory of Green Chemistry & Technology of MOE, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China.
  • Hou X; Analytical & Testing Centre, Sichuan University, Chengdu, Sichuan 610064, China.
Anal Chem ; 94(51): 17746-17750, 2022 12 27.
Article em En | MEDLINE | ID: mdl-36480455
ABSTRACT
DNA-based logic computing potentially for analysis of biomarker inputs and generation of oligonucleotide signal outputs is of great interest to scientists in diverse areas. However, its practical use for sensing of multiple biomarkers is limited by the universality and robustness. Based on a proximity assay, a lanthanide encoded logically gated micromachine (LGM-Ln) was constructed in this work, which is capable of responding to multiplex inputs in biological matrices. Under the logic function controls triggered by inputs and a Boolean "AND" algorithm, it is followed by an amplified "ON" signal to indicate the analytes (inputs). In this logically gated sensing system, the whole computational process does not involve strand displacement in an intermolecular reaction, and a threshold-free design is employed to generate the 0 and 1 computation via intraparticle cleavage, which facilitates the computation units and makes the "computed values" more reliable. By simply altering the affinity ligands for inputs' biorecognition, LGM-Ln can also be extended to multi-inputs mode and produce the robust lanthanide encoded outputs in the whole human serum for sensing nucleic acids (with the detection limit of 10 pM) and proteins (with the detection limit of 20 pM). Compared with a logically gated micromachine encoded with fluorophores, the LGM-Ln has higher resolution and no spectral overlaps for multiple inputs, thus holding great promise in multiplex analyses and clinical diagnosis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Nucleicos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Nucleicos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article