Your browser doesn't support javascript.
loading
Intrasession and Intersession Reliability of Isometric Squat, Midthigh Pull, and Squat Jump in Resistance-Trained Individuals.
Ishida, Ai; Suarez, Dylan G; Travis, S Kyle; Slaton, Jake A; White, Jason B; Bazyler, Caleb D; Stone, Michael H.
Afiliação
  • Ishida A; School of Applied Health Sciences and Wellness, Ohio University, Grove Center, Athens, Ohio.
  • Suarez DG; Exercise and Sport Sciences Laboratory, East Tennessee State University, Johnson City, Tennessee.
  • Travis SK; Exercise and Sport Sciences Laboratory, East Tennessee State University, Johnson City, Tennessee.
  • Slaton JA; College of Public Health and Health Professions, University of Florida, Gainesville, Florida; and.
  • White JB; Exercise and Sport Sciences Laboratory, East Tennessee State University, Johnson City, Tennessee.
  • Bazyler CD; School of Applied Health Sciences and Wellness, Ohio University, Grove Center, Athens, Ohio.
  • Stone MH; Exercise and Sport Sciences Laboratory, East Tennessee State University, Johnson City, Tennessee.
J Strength Cond Res ; 37(1): 18-26, 2023 Jan 01.
Article em En | MEDLINE | ID: mdl-36515586
ABSTRACT
ABSTRACT Ishida, A, Suarez, DG, Travis, SK, Slaton, JA, White, JB, Bazyler, CD, and Stone, MH. Intrasession and intersession reliability of isometric squat, midthigh pull, and squat jump in resistance-trained individuals. J Strength Cond Res 37(1) 18-26, 2023-The purposes of this study were to investigate intrasession and intersession reliability of variables obtained from squat jump (SJ), shortened isometric midthigh pull (IMTP), and isometric squat (ISQ) protocols and to evaluate relationships between isometric and dynamic performance and 1 repetition maximum (1RM) back squat (BSQ). Eleven moderately resistance-trained men participated (27.8 ± 3.9 years; 175.0 ± 7.2 cm; 87.2 ± 11.4 kg). Subjects completed familiarization in the IMTP and ISQ, followed by 1RM BSQ at least 48 hours before the first performance test. Two performance tests occurred at 7-day intervals including SJ, IMTP, and ISQ. SJ variables included jump height (SJH), body mass (BM), peak force (PF), and peak power (PP). Isometric midthigh pull and ISQ variables included isometric peak force (IPF); relative IPF; rate of force development at 90, 200, and 250 milliseconds; and impulse at 90, 200, and 250 milliseconds. SJ, IMTP, and ISQ kinetic variables were considered reliable if intraclass correlations (ICCs) and coefficients of variations (CVs) were >0.80 and <10%. Intrasession and intersession reliability criteria were met for SJH, BM, PF, and PP (ICC = 0.91-1.00, CV = 0.5-9.1%). Isometric peak force and impulse at 200 and 250 milliseconds met intrasession and intersession reliability criteria for IMTP and ISQ (ICC = 0.90-0.99, CV = 2.1-8.1%). Significant large correlation was observed between 1RM BSQ and ISQ peak force (p = 0.038, r = 0.63), but not between 1RM BSQ and shortened IMTP peak force (p = 0.11, r = 0.50). Shortened IMTP and ISQ peak force and impulse are reliable kinetic variables, and ISQ peak force is indicative of 1RM BSQ in moderately resistance-trained men.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Força Muscular / Contração Isométrica Limite: Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Força Muscular / Contração Isométrica Limite: Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article